PrintCopy.info service

Brother HL-L2312D

Error Codes List page 2

  • Code: 0501
  • Description: The center thermistor of the fuser unit has not reached the specified temperature within the specified time.
  • Remedy: <User Check>
    • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit.
    2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit.
    3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness.
    4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness.
    5 Eject sensor PCB failure Replace the eject sensor PCB ASSY.
    6 Fuser unit failure Replace the fuser unit.
    7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY.
    8 Main PCB failure Replace the main PCB ASSY.
  • Code: 0502
  • Description: The center thermistor of the fuser unit has not reached the specified temperature within the specified time after it was heated normally to the certain level.
  • Remedy: <User Check>
    • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit.
    2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit.
    3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness.
    4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness.
    5 Eject sensor PCB failure Replace the eject sensor PCB ASSY.
    6 Fuser unit failure Replace the fuser unit.
    7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY.
    8 Main PCB failure Replace the main PCB ASSY.
  • Code: 0503
  • Description: The center thermistor of the fuser unit detected a temperature higher than the specified value.
  • Remedy: <User Check>
    • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit.
    2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit.
    3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness.
    4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness.
    5 Eject sensor PCB failure Replace the eject sensor PCB ASSY.
    6 Fuser unit failure Replace the fuser unit.
    7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY.
    8 Main PCB failure Replace the main PCB ASSY.
  • Code: 0504
  • Description: After the heat unit was heated normally, the center thermistor of the fuser unit detected a temperature lower than the specified value.
  • Remedy: <User Check>
    • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit.
    2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit.
    3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness.
    4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness.
    5 Eject sensor PCB failure Replace the eject sensor PCB ASSY.
    6 Fuser unit failure Replace the fuser unit.
    7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY.
    8 Main PCB failure Replace the main PCB ASSY.
  • Code: 0505
  • Description: The center thermistor of the fuser unit detected a temperature rise greater than the specified value within the specified time.
  • Remedy: <User Check>
    • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit.
    2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit.
    3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness.
    4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness.
    5 Eject sensor PCB failure Replace the eject sensor PCB ASSY.
    6 Fuser unit failure Replace the fuser unit.
    7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY.
    8 Main PCB failure Replace the main PCB ASSY.
  • Code: 0506
  • Description: The center thermistor of the fuser unit detected a temperature fall greater than the specified value within the specified time.
  • Remedy: <User Check>
    • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit.
    2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit.
    3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness.
    4 Connection failure of the lowvoltage power supply PCB harness Reconnect the low-voltage power supply PCB harness.
    5 Eject sensor PCB failure Replace the eject sensor PCB ASSY.
    6 Fuser unit failure Replace the fuser unit.
    7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY.
    8 Main PCB failure Replace the main PCB ASSY.