  • Code: 6C
  • Description: Heater temperature exceeds the maximum high temperature. (270°C or more is detected for 1 sec.)
  • Causes: • Thermistor ASSY • Power supply PCB
  • Code: 6D
  • Description: Heater temperature lowers the minimum low temperature. (60°C or less is detected for 1 sec.)
  • Causes: • Thermistor ASSY • Power supply PCB
  • Code: 6E
  • Description: Heater temperature does not go up enough. (Slower temperature rise rate than 2°C/5 sec. is detected.)
  • Causes: • Halogen lamp • Power supply PCB
  • Code: 6F
  • Description: Heater hard limiter operates.
  • Causes: • Thermistor ASSY • Power supply PCB
  • Code: 71
  • Description: Scanner motor does not synchronize with the reference clock.
  • Causes: • Scanner motor
  • Code: 72
  • Description: Cannot detect Beam Detect signal.
  • Causes: • Scanner motor • MP tray open sensor