  • Code: 050A
  • Display: Print Unable 05 Turn the power off and then back on again.
  • Description: The center thermistor or side thermistor of the fuser unit detected some temperature error in the hardware.
  • Remedy: < User Check > - Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the harness of the center thermistor or side thermistor of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the low-voltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB unit. 8 Main PCB failure Replace the main PCB ASSY.
  • Code: 050B
  • Display: Print Unable 05 Turn the power off and then back on again.
  • Description: When the temperature of the center thermistor of the fuser unit is lower than the idle temperature, the side thermistor of the fuser unit detected a temperature higher than the specified value.
  • Remedy: < User Check > - Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the harness of the center thermistor or side thermistor of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the low-voltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB unit. 8 Main PCB failure Replace the main PCB ASSY.
  • Code: 050C
  • Display: Print Unable 05 Turn the power off and then back on again.
  • Description: When the temperature of the center thermistor of the fuser unit is higher than the idle temperature, the side thermistor of the fuser unit detected a temperature lower than the specified value.
  • Remedy: < User Check > - Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the harness of the center thermistor or side thermistor of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the eject sensor PCB harness Reconnect the eject sensor PCB harness. 4 Connection failure of the low-voltage power supply PCB harness Reconnect the low-voltage power supply PCB harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB unit. 8 Main PCB failure Replace the main PCB ASSY.
  • Code: 0800
  • Display: Print Unable 08 Turn the power off and then back on again.
  • Description: Error occurred in the internal temperature sensor.
  • Remedy: 1 Connection failure of the internal temperature sensor harness Reconnect the internal temperature sensor harness. 2 Main PCB failure Replace the main PCB ASSY.
  • Code: 0900
  • Display: Print Unable 09 Turn the power off and then back on again.
  • Description: Machine detected more than 100 times that supplied power was unstable.
  • Remedy: < User Check > - Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB unit. After replacing the low-voltage power supply PCB unit (Function code 88), and reset the irregular power supply detection counter of the low-voltage power supply PCB unit. 2 Main PCB failure Replace the main PCB ASSY.
    Note: The irregular power supply detection error (Error code 0900) of the low-voltage power supply PCB unit occurs when there is a large distortion in the power supply voltage supplied to the machine. In this case, if the same power supply is used, the same error might occur again even if the low-voltage power supply PCB unit is replaced. For this reason, be sure to ask the user to rearrange the installation environment.
  • Code: 0A01
  • Display: Print Unable 0A Turn the power off and then back on again.
  • Description: The blower failure was detected.
  • Remedy: 1 Connection failure of the blower harness Reconnect the blower harness. 2 Connection failure of the high-voltage power supply PCB harness Reconnect the high-voltage power supply PCB harness. 3 Blower failure Replace the blower. 4 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB unit. 5 High-voltage power supply PCB failure Replace the high-voltage power supply PCB ASSY. 6 Main PCB failure Replace the main PCB ASSY.