PrintCopy.info service

Brother DCP-L5650DN

Error Codes List page 3

  • Code: 0506
  • Description: The center thermistor of the fuser unit detected a temperature fall greater than the specified value within the specified time.
  • Remedy: 1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the fuser unit heater harness Reconnect the fuser unit heater harness. 3 Connection failure of the eject sensor harness Reconnect the eject sensor harness. 4 Connection failure of the lowvoltage power supply harness Reconnect the low-voltage power supply harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
  • Code: 0508
  • Description: The side thermistor of the fuser unit did not detect a temperature rise when the heater was ON.
  • Remedy: 1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the fuser unit heater harness Reconnect the fuser unit heater harness. 3 Connection failure of the eject sensor harness Reconnect the eject sensor harness. 4 Connection failure of the lowvoltage power supply harness Reconnect the low-voltage power supply harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
  • Code: 050A
  • Description: The hardware detected a temperature error through the center thermistor or the side thermistor of the fuser unit.
  • Remedy: 1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the fuser unit heater harness Reconnect the fuser unit heater harness. 3 Connection failure of the eject sensor harness Reconnect the eject sensor harness. 4 Connection failure of the lowvoltage power supply harness Reconnect the low-voltage power supply harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
  • Code: 050B
  • Description: When the center thermistor of the fuser unit was lower than the idle temperature, the side thermistor detected a temperature higher than the specified temperature.
  • Remedy: 1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the fuser unit heater harness Reconnect the fuser unit heater harness. 3 Connection failure of the eject sensor harness Reconnect the eject sensor harness. 4 Connection failure of the lowvoltage power supply harness Reconnect the low-voltage power supply harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
  • Code: 050C
  • Description: When the center thermistor of the fuser unit was higher than the idle temperature, the side thermistor detected a temperature lower than the specified temperature.
  • Remedy: 1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit. 2 Connection failure of the fuser unit heater harness Reconnect the fuser unit heater harness. 3 Connection failure of the eject sensor harness Reconnect the eject sensor harness. 4 Connection failure of the lowvoltage power supply harness Reconnect the low-voltage power supply harness. 5 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 6 Fuser unit failure Replace the fuser unit. 7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 8 Main PCB failure Replace the main PCB ASSY.
  • Code: 0800
  • Description: An error occurred in the internal temperature sensor.
  • Remedy: 1 Connection failure of the internal temperature sensor harness Reconnect the internal temperature sensor harness. 2 Internal temperature sensor failure Replace the main frame L ASSY. 3 Main PCB failure Replace the main PCB ASSY.