PrintCopy.info service

Brother DCP-L3517CDW

Error Codes List page 1

  • Code: 0101
  • Description: ASIC error or motor driver error occurred.
  • Remedy: 1 Main PCB failure
    Replace the main PCB.
  • Code: 0201
  • Description: Cannot detect the synchronized signal of the paper feed motor. The speed of the paper feed motor does not stabilize within the specified time.
  • Remedy: 1 Connection failure of the paper feed motor flat cable. Reconnect the paper feed motor flat cable.
    2 Connection failure of the low-voltage power supply harness Reconnect the low-voltage power supply harness.
    3 Paper feed motor flat cable failure Replace the paper feed motor flat cable.
    4 Damaged parts in paper feed drive unit Replace the paper feed drive unit.
    5 Damaged parts in process drive unit Replace the process drive unit.
    6 Damaged fuser unit Replace the fuser unit.
    7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB.
    8 Main PCB failure Replace the main PCB.
  • Code: 0202
  • Description: Cannot detect the synchronized signal of the process motor. The speed of the process motor does not stabilize within the specified time.
  • Remedy: 1 Connection failure of the process motor flat cable Reconnect the process motor flat cable.
    2 Connection failure of the low-voltage power supply harness Reconnect the low-voltage power supply harness.
    3 Process motor flat cable failure Replace the process motor flat cable.
    4 Damaged parts in process drive unit Replace the process drive unit.
    5 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB.
    6 Main PCB failure Replace the main PCB.
  • Code: 0501
  • Description: The center thermistor of the fuser unit has not reached the specified temperature within the specified time.
  • Remedy: <User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit.
    2 Connection failure of the fuser unit heater harness Reconnect the fuser unit heater harness.
    3 Connection failure of the eject sensor harness Reconnect the eject sensor harness.
    4 Connection failure of the lowvoltage power supply harness Reconnect the low-voltage power supply harness.
    5 Eject sensor PCB failure Replace the eject sensor PCB.
    6 Fuser unit failure Replace the fuser unit.
    7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB.
    8 Main PCB failure Replace the main PCB.
  • Code: 0502
  • Description: The center thermistor of the fuser unit has not reached the specified temperature within the specified time after it was heated normally to the certain level.
  • Remedy: <User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit.
    2 Connection failure of the fuser unit heater harness Reconnect the fuser unit heater harness.
    3 Connection failure of the eject sensor harness Reconnect the eject sensor harness.
    4 Connection failure of the lowvoltage power supply harness Reconnect the low-voltage power supply harness.
    5 Eject sensor PCB failure Replace the eject sensor PCB.
    6 Fuser unit failure Replace the fuser unit.
    7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB.
    8 Main PCB failure Replace the main PCB.
  • Code: 0503
  • Description: The center thermistor of the fuser unit detected a temperature higher than the specified value.
  • Remedy: <User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit Reconnect the center or side thermistor harness of the fuser unit.
    2 Connection failure of the fuser unit heater harness Reconnect the fuser unit heater harness.
    3 Connection failure of the eject sensor harness Reconnect the eject sensor harness.
    4 Connection failure of the lowvoltage power supply harness Reconnect the low-voltage power supply harness.
    5 Eject sensor PCB failure Replace the eject sensor PCB.
    6 Fuser unit failure Replace the fuser unit.
    7 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB.
    8 Main PCB failure Replace the main PCB.