Description: This error does not usually occur during normal use. The possible causes are noise around the installation site, fluctuation of the power supply voltage, and failures in the software. An unidentified error occurred.
Remedy: 1 Main PCB failure Replace the main PCB ASSY.
Code: AB00
Display: Multifeed Press Stop and reinsert the document.
Description: The double feeding sensor detected multiple documents.
Remedy: <User Check> • Check that the thickness of the paper is within the standard. • Check that the number of documents set in each tray is within the standard. 1 Incorrect double feeding sensor threshold setting Reset the double feeding sensor threshold. 2 Double feeding sensor (Sent/ Receive) failure Replace the double feeding sensor (Sent/ Receive). 3 Key PCB failure Replace the key PCB ASSY. 4 Main PCB failure Replace the main PCB ASSY.
Code: AC00 ... AF00
Display:
Description: These errors do not usually occur during normal use. The possible causes are noise around the installation site, fluctuation of the power supply voltage, and failures in the software. An unidentified error occurred.
Remedy: 1 Main PCB failure Replace the main PCB ASSY.
Code: B000
Display:
Description: The first side or second side CIS flat cable is not connected correctly.
Remedy: 1 Connection failure of the first side or second side CIS flat cable Reconnect the first side or second side CIS flat cable. 2 First side or second side CIS unit failure Replace the first side or second side CIS unit. 3 Main PCB failure Replace the main PCB ASSY.
Code: B100 ... B700
Display:
Description: These errors do not usually occur during normal use. The possible causes are noise around the installation site, fluctuation of the power supply voltage, and failures in the software. An unidentified error occurred.
Remedy: 1 Main PCB failure Replace the main PCB ASSY.
Code: B800
Display:
Description: The voltage value was below the lower limit during scanning.
Remedy: 1 First side or second side CIS unit failure Replace the first side or second side CIS unit. 2 Main PCB failure Replace the main PCB ASSY.