  • Code: C010
  • Description: Main motor abnormality: The main motor is not rotating normally.
  • Remedy: Is the main motor working? (Perform the output check in the test mode: 03-101/151) NO 1) Check if the connector CN1 of the main motor is disconnected. 2) Check if the connector CN305 on the LGC board is disconnected. 3) Check if the connector pins are disconnected and the harnesses are open circuited. 4) Check if the conductor patterns on the main motor board and LGC board are short circuited or open circuited. 5) Replace the main motor. 6) Replace the LGC board. YES Is the LED on the main motor board lit without flickering? NO 1) Check if the connector pins are disconnected and the harnesses are open circuited. 2) Check if the conductor patterns on the main motor board and LGC board are short circuited or open circuited. 3) Replace the main motor. 4) Replace the LGC board. YES 1) Check if the PLL lock signal CN305-B8 output from the LGC board is always level “L”? 2) Check if the voltage supplied to the CPU input terminal IC24-12 is always “L”? 3) Replace the LGC board.
  • Code: C040
  • Description: PFP motor abnormality: The PFP motor is not rotating normally.
  • Remedy: Is the PFP motor working? (Perform the output check in the test mode: 03-109/159) NO 1) Check if the signal line connector CN503 of the PFP motor is disconnected. 2) Check if the power line connector CN502 of the PFP motor is disconnected. 3) Check if the connector CN246 on the PFP board is disconnected. 4) Check if the signal line connector CN241 on the PFP board is disconnected. 5) Check if the power line connector CN242 on the PFP board is disconnected. 6) Check if the connector CN310 on the LGC board is disconnected. 7) Check if the connector pins are disconnected and the harnesses are open circuited. 8) Check if the conductor patterns on the PFP motor board, PFP board and LGC board are short circuited or open circuited. 9) Replace the PFP motor. 10)Replace the PFP board. 11)Replace the LGC board. YES Is the LED on the PFP motor board lit without flickering? NO 1) Check if the connector pins are disconnected and the harnesses are open circuited. 2) Check if the conductor patterns on the PFP motor board, PFP board and LGC board are short circuited or open circuited. 3) Replace the PFP motor. 4) Replace the PFP board. 5) Replace the LGC board. YES 1) Check if the PLL lock signal CN246-8 output from the PFP board is always “L” level. 2) Check if the voltage supplied to the microcomputer input terminal IC5-17 is always “L” level. 3) Replace the PFP board. 4) Replace the LGC board.
  • Code: C130
  • Description: Upper drawer tray abnormality: The upper drawer tray motor is not rotating or the upper drawer tray is not moving normally.
  • Remedy: Does the tray go up? (Perform the output check in the test mode: 03-242/243) NO 1) Check if the connector of the tray-up motor is disconnected. 2) Check if the connector CN307 on the LGC board is disconnected. 3) Check if the connector pins are disconnected and the harnesses are open circuited. 4) Check if the conductor pattern on the LGC board is short circuited or open circuited. 5) Replace the LGC board. YES Is the tray-up sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[6]/[H], /[7]/[H]) NO 1) Check if the connector of the sensor is disconnected. 2) Check if the connector CN307 on the LGC board is disconnected. 3) Check if the slit reaches the sensor. 4) Check if the connector pins are disconnected and the harnesses are open circuited. 5) Check if the conductor pattern on the LGC board is short circuited or open circuited. 6) Replace the LGC board. YES 1) Check if the conductor pattern on the LGC board is short circuited or open circuited. 2) Replace the LGC board.
  • Code: C140
  • Description: Lower drawer tray abnormality: The lower drawer tray motor is not rotating or the lower drawer tray is not moving normally.
  • Remedy: Does the tray go up? (Perform the output check in the test mode: 03-242/243) NO 1) Check if the connector of the tray-up motor is disconnected. 2) Check if the connector CN307 on the LGC board is disconnected. 3) Check if the connector pins are disconnected and the harnesses are open circuited. 4) Check if the conductor pattern on the LGC board is short circuited or open circuited. 5) Replace the LGC board. YES Is the tray-up sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[6]/[H], /[7]/[H]) NO 1) Check if the connector of the sensor is disconnected. 2) Check if the connector CN307 on the LGC board is disconnected. 3) Check if the slit reaches the sensor. 4) Check if the connector pins are disconnected and the harnesses are open circuited. 5) Check if the conductor pattern on the LGC board is short circuited or open circuited. 6) Replace the LGC board. YES 1) Check if the conductor pattern on the LGC board is short circuited or open circuited. 2) Replace the LGC board.
  • Code: C150
  • Description: PFP upper drawer tray abnormality: The PFP upper drawer tray motor is not rotating or the PFP upper drawer tray is not moving normally.
  • Remedy: Does the tray go up? (Perform the output check in the test mode: 03-278/280) NO 1) Check if the connector of the tray-up motor is disconnected. 2) Check if any of the connectors CN241, CN242 and CN244 on the PFP board is disconnected. 3) Check if the connector CN310 on the LGC board is disconnected. 4) Check if the connector pins are disconnected and the harnesses are open circuited. 5) Check if the conductor patterns on the PFP board and LGC board are short circuited or open circuited. 6) Replace the PFP board. 7) Replace the LGC board. YES Is the tray-up sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[2]/[H], /[4]/[H]) NO 1) Check if the connector of the sensor is disconnected. 2) Check if any of the connectors CN241, CN247 and CN248 on the PFP board is disconnected. 3) Check if the connector CN310 on the LGC board is disconnected. 4) Check if the slit reaches the sensor. 5) Check if the connector pins are disconnected and the harnesses are open circuited. 6) Check if the conductor patterns on the PFP board and LGC board are short circuited or open circuited. 7) Replace the PFP board. 8) Replace the LGC board. YES 1) Check if the conductor pattern on the LGC board is short circuited or open circuited. 2) Replace the LGC board.
  • Code: C160
  • Description: PFP lower drawer tray abnormality: The PFP lower drawer tray motor is not rotating or the PFP lower drawer tray is not moving normally.
  • Remedy: Does the tray go up? (Perform the output check in the test mode: 03-278/280) NO 1) Check if the connector of the tray-up motor is disconnected. 2) Check if any of the connectors CN241, CN242 and CN244 on the PFP board is disconnected. 3) Check if the connector CN310 on the LGC board is disconnected. 4) Check if the connector pins are disconnected and the harnesses are open circuited. 5) Check if the conductor patterns on the PFP board and LGC board are short circuited or open circuited. 6) Replace the PFP board. 7) Replace the LGC board. YES Is the tray-up sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[2]/[H], /[4]/[H]) NO 1) Check if the connector of the sensor is disconnected. 2) Check if any of the connectors CN241, CN247 and CN248 on the PFP board is disconnected. 3) Check if the connector CN310 on the LGC board is disconnected. 4) Check if the slit reaches the sensor. 5) Check if the connector pins are disconnected and the harnesses are open circuited. 6) Check if the conductor patterns on the PFP board and LGC board are short circuited or open circuited. 7) Replace the PFP board. 8) Replace the LGC board. YES 1) Check if the conductor pattern on the LGC board is short circuited or open circuited. 2) Replace the LGC board.