PrintCopy.info service

Sharp MXB402

  • Code: L4-06
  • Description: Transfer unit lift trouble
  • Causes: Transfer unit position sensor trouble. PCU PWB trouble. Connection trouble of the connector and the harness. Transfer unit separation clutch operation trouble. Primary transfer belt unit is not installed.
  • Remedy: Use SIM6-3 to check the separating operation of the transfer unit. Install the primary transfer belt unit. Replace the transfer unit position sensor. Replace the PCU PWB. Harness and connector connection trouble. Replace the transfer unit separation clutch.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home