  • Code: E-12
  • Description: Pressure Plate error The pressure plate home position sensor does not turn on within 6 seconds during initialization. Both the pressure plate home position and pressure plate limit sensors turn on when the main SW is turned on. The pressure plate home position sensor does not turn off when the pressure plate limit sensor does not turn on within 4.5 seconds when compressing the ejected master.
  • Causes: Pressure plate drive Pressure plate motor Plate position sensors Master eject error