Description: Polygonal Mirror Motor Cooling Fan Motor Lock
The polygonal mirror motor cooling fan motor lock signal remains HIGH for 5s while the polygonal mirror motor cooling fan motor is on.
Causes: • Drive mechanism overload • Obstruction has stopped the fan • Fan connector loose