Description: • The control ROM is in abnormal conditions.
Remedy: 1) Replace the main PCB with a new one.
Code: 02
Display: ERROR 02 MAIN RAM
Description: • The control RAM is in abnormal conditions.
Remedy: 1) Replace the main PCB with a new one.
Code: 03
Display: ERROR 03 POWER +5V POWER +35V
Description: • The +5V (+35V) voltage is in abnormal conditions.
Remedy: 1) Replace the power supply or the main PCB with a new one.
Code: 04
Display: ERROR 04 FLASH SAVE
Description: • The Flash memory is in abnormal conditions.
Remedy: 1) Replace the main PCB with a new one.
Code: 05
Display: ERROR 05 FPGA ss
Description: • FPGA configuration error
Remedy: 1) Replace the main PCB with a new one.
Code: 06
Display: ERROR 06 UHC 01 nnnn
Description: Band memory configured incorrectly. n=UHC No.1-8
Remedy: 1) Check that UHCII PCB is inserted securely in the main PCB. 2) Turn ON/OFF the plotter and check the problem disappears. 3) Upgrade the firmware.