PrintCopy.info service

Mimaki UJF605CII

Error Codes List page 1

  • Code: 01
  • Display: ERROR 01 MAIN ROM
  • Description: • The control ROM is in abnormal conditions.
  • Remedy: 1) Replace the main PCB with a new one.
  • Code: 02
  • Display: ERROR 02 MAIN RAM
  • Description: • The control RAM is in abnormal conditions.
  • Remedy: 1) Replace the main PCB with a new one.
  • Code: 03
  • Display: ERROR 03 POWER +5V POWER +35V
  • Description: • The +5V (+35V) voltage is in abnormal conditions.
  • Remedy: 1) Replace the power supply or the main PCB with a new one.
  • Code: 04
  • Display: ERROR 04 FLASH SAVE
  • Description: • The Flash memory is in abnormal conditions.
  • Remedy: 1) Replace the main PCB with a new one.
  • Code: 05
  • Display: ERROR 05 FPGA ss
  • Description: • FPGA configuration error
  • Remedy: 1) Replace the main PCB with a new one.
  • Code: 06
  • Display: ERROR 06 UHC 01 nnnn
  • Description: Band memory configured incorrectly. n=UHC No.1-8
  • Remedy: 1) Check that UHCII PCB is inserted securely in the main PCB. 2) Turn ON/OFF the plotter and check the problem disappears. 3) Upgrade the firmware.