  • Code: 01
  • Display: ERROR 01 MAIN ROM
  • Description: An error occurs on the control PCB (ROM)
  • Remedy: Turn off the main power, and turn it on a little later. If the error occurs again, carry out the followings. 1. Replace the main PCB assy.
  • Code: 02
  • Display: ERROR 02 MAIN RAM
  • Description: An error occurs on the control PCB (RAM)
  • Remedy: Turn off the main power, and turn it on a little later. If the error occurs again, carry out the followings. 1. Replace the main PCB assy.
  • Code: 03
  • Display: ERROR 03 POWER +5V
  • Description: An error occurs on the control PCB (Power voltage +5V)
  • Remedy: Turn off the main power, and turn it on a little later. If the error occurs again, carry out the followings. 1. Replace the power supply PCB assy. 2. Replace the main PCB assy.
  • Code: 03
  • Display: ERROR 03 POWER +24V
  • Description: An error occurs on the control PCB (Power voltage +24V)
  • Remedy: Turn off the main power, and turn it on a little later. If the error occurs again, carry out the followings. 1. Replace the power supply PCB assy. 2. Replace the main PCB assy.
  • Code: 03
  • Display: ERROR 03 POWER +42V
  • Description: An error occurs on the control PCB (Power voltage +42V)
  • Remedy: Turn off the main power, and turn it on a little later. If the error occurs again, carry out the followings. 1. Replace the power supply PCB assy. 2. Replace the main PCB assy.
  • Code: 04
  • Display: ERROR 04 F-ROM
  • Description: An error occurs on the control PCB (Parameter ROM)
  • Remedy: Turn off the main power, and turn it on a little later. If the error occurs again, carry out the followings. 1. After uploading parameters, initialize all parameters. If the state is not restored, replace the main PCB assy with a new one.