  • Code: 6030
  • Description: Broken fuser thermistor 2 wire A/D value of the fuser thermistor 2 exceeds 1019 bit continuously for 4 s during warming up.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser thermistor and fuser thermistor connect PWB(YC2) Fuser thermistor connect PWB(YC3) and engine PWB (YC21)
    Deformed connector pin.
    Defective triac.
    Defective fuser thermistor. Replace the fuser unit.
    Defective engine PWB. Replace the engine PWB and check for correct operation.