Error Codes List page 1

  • Code: 01-11, 01-12, 01-13
  • Description: Cutter Error 01-11: Deck 1 01-12: Deck 2 01-13: Deck 3
  • Causes: Blade not detected at HP within 2 seconds.
  • Remedy: First of all, run Service Software “output check” to monitor the motion of Cutter Motor. The subsequent procedure depends on whether the motor operates.
    Cutter Motor NOT operate:
    Harness 1 Is the wiring OK between the followings? Cutter Motor (M7/M8/M9) Cutter HP Sensor (MS9, MS10/MS11, MS12/MS13, MS14) Deck Drive PCB (PW12557A/B/C) No Correct it.
    Cutter Motor (M7/M8/M9) 2 Check for wiring on Cutter Unit. (Cutter Motor, harnesses) Is the problem gone? No Replace Cutter Unit.
    Fuse F7 3 Check for continuity of Fuse F7. Is it OK? No Fuse broken: Check all the downstream components to eliminate the root cause first, and then replace the fuse.
    Deck Drive PCB (PW12557A/B/C) 4 Can the problem be fixed by replacing the Deck Drive PCB? Yes OK
    Main Control PCB (PW12520) 5 Can the problem be fixed by replacing the Main Control PCB? Yes OK
    Cutter Motor OK:
    Harness 1 Is the wiring OK between the followings? Cutter Motor (M7/M8/M9) Cutter HP Sensor (MS9, MS10/MS11, MS12/MS13, MS14) Deck Drive PCB (PW12557A/B/C) No Correct it.
    Cutter HP Sensor (MS9, MS10/ MS11, MS12/ MS13, MS14) 2 Run Service Software “input check” to monitor the status of the sensor. 0608: Deck 1 Home Position R 0609: Deck 1 Home Position L 0708: Deck 2 Home Position R 0709: Deck 2 Home Position L 0809: Deck 3 Home Position R 080A: Deck 3 Home Position L Does the status change at the time the cutter blade moves from its HP? No Check for wiring on Cutter HP Sensor. If still unsettled, replace Cutter Unit.
    Deck Drive PCB (PW12557A/B/C) 3 Can the problem be fixed by replacing the Deck Drive PCB? Yes OK
    Main Control PCB (PW12520) 4 Can the problem be fixed by replacing the Main Control PCB? Yes OK
  • Code: 03-01
  • Description: Dev Press Motor 1 Error
  • Causes: (1) Developer Unit (K) is not placed to the setting position although 9 seconds has passed. (2) Developer Unit (K) is not separated although 9 seconds has passed.
  • Remedy: First of all, run Service Software “output check” No.010B to monitor the motion of Dev Press Motor 1. The subsequent procedure depends on whether the motor operates.
    Dev Press Motor 1 NOT operate:
    Harness 1 Is the wiring OK between the followings? Dev Press Motor 1 (M18) Dev Drive PCB (PW12555A) Fuse F1 No Correct it.
    Dev Press Motor 1 (M18) Dev Drive PCB (PW12555A) 2 Can the problem be fixed by replacing Dev Press Motor or Dev Drive PCB? Yes OK
    Fuse F1 3 Check for continuity of Fuse F1. Is it OK? No Fuse broken: Check all the downstream components to eliminate the root cause first, and then replace the fuse.
    Main Control PCB (PW12520) 4 Can the problem be fixed by replacing the Main Control PCB? Yes OK
    Dev Press Motor 1 OK:
    Harness 1 Is the wiring OK between Dev Press Sensor (PH26) and Dev Drive PCB (PW12555A)? No Correct it.
    Dev Press Sensor (PH26) 2 Can the problem be fixed by replacing Dev Press Sensor? Yes OK
    Dev Drive PCB (PW12555A) 3 Can the problem be fixed by replacing Dev Drive PCB? Yes OK
    Main Control PCB (PW12520) 4 Can the problem be fixed by replacing the Main Control PCB? Yes OK
  • Code: 03-02
  • Description: Drum Motor 1 Error
  • Causes: “Abnormal output signal” shows “1” for longer than 100msec.
  • Remedy: First of all, run Service Software “output check” No.0106 to monitor the motion of Drum Motor 1. The subsequent procedure depends on whether the motor operates.
    Drum Motor 1 NOT operate:
    Harness 1 Is the wiring OK between the followings? Drum Motor 1 (M12) Dev Drive PCB (PW12555A) Fuse F1 No Correct it.
    Drum Motor 1 (M18) Dev Drive PCB (PW12555A) 2 Can the problem be fixed by replacing Drum Motor or Dev Drive PCB? Yes OK
    Fuse F1 3 Check for continuity of Fuse F1. Is it OK? No Fuse broken: Check all the downstream components to eliminate the root cause first, and then replace the fuse.
    Main Control PCB (PW12520) 4 Can the problem be fixed by replacing the Main Control PCB? Yes OK
    Drum Motor 1 OK:
    Harness 1 Is the wiring OK between Drum Motor Sensors (PH29, PH30) and Dev Drive PCB (PW12555A)? No Correct it.
    Drum Motor Sensor (PH29, PH30) 2 Can the problem be fixed by replacing Drum Motor Sensor? Yes OK
    Dev Drive PCB (PW12555A) 3 Can the problem be fixed by replacing Dev Drive PCB? Yes OK
    Main Control PCB (PW12520) 4 Can the problem be fixed by replacing the Main Control PCB? Yes OK
  • Code: 03-20
  • Description: Image Corona 1 Output Error
  • Causes: “Abnormal output signal” shows “1” for longer than 100msec.
  • Remedy: Harness 1 Is the wiring OK between HV Power Supply PCB 1 (HVP1) and Dev Drive PCB (PW12555A)? No Correct it.
    HV1 Harness Image Corona Wire 2 Is there any resistance between HV1 harness on HVP1 and the ground? No Check HV1 harness and Image Corona Wire.
    HV Power Supply PCB 1 (HVP1) 3 Can the problem be fixed by replacing the HV Power Supply PCB 1? Yes OK
    Dev Drive PCB (PW12555A) 4 Can the problem be fixed by replacing the Dev Drive PCB? Yes OK
    Main Control PCB (PW12520) 5 Can the problem be fixed by replacing the Main Control PCB? Yes OK
  • Code: 03-21
  • Description: Transfer Roller Bias 1 Output Error
  • Causes: “Abnormal output signal” shows “1” for longer than 100msec.
  • Remedy: Harness 1 Is the wiring OK between HV Power Supply PCB 1 (HVP1) and Dev Drive PCB (PW12555A)? No Correct it.
    HV1 Harness Transfer Roller 1 2 Is there any resistance between HV2 harness on HVP1 and the ground? No Check HV2 harness and Transfer Roller.
    HV Power Supply PCB 1 (HVP1) 3 Can the problem be fixed by replacing the HV Power Supply PCB 1? Yes OK
    Dev Drive PCB (PW12555A) 4 Can the problem be fixed by replacing the Dev Drive PCB? Yes OK
    Main Control PCB (PW12520) 5 Can the problem be fixed by replacing the Main Control PCB? Yes OK
  • Code: 03-23
  • Description: Developer Bias 1 Output Error
  • Causes: “Abnormal output signal” shows “1” for longer than 100msec.
  • Remedy: Harness 1 Is the wiring OK between HV Power Supply PCB 1 (HVP1) and Dev Drive PCB (PW12555A)? No Correct it.
    HV1 Harness Developer Unit (K) 2 Is there any resistance between OUT2 harness on HVP1 and the ground? No Check OUT2 harness and Developer Unit.
    HV Power Supply PCB 1 (HVP1) 3 Can the problem be fixed by replacing the HV Power Supply PCB 1? Yes OK
    Dev Drive PCB (PW12555A) 4 Can the problem be fixed by replacing the Dev Drive PCB? Yes OK
    Main Control PCB (PW12520) 5 Can the problem be fixed by replacing the Main Control PCB? Yes OK
Error Code