  • Code: 6C
  • Description: Fuser unit error. (The center thermistor detects 270°C or higher temperature for 1 second.)
  • Causes:
  • Remedy: 1 Fuser unit connector connection failure Check the connector connection of the fuser unit and reconnect it. 2 Fuser unit failure Replace the fuser unit. 3 Low voltage power supply PCB failure Replace the low voltage power supply PCB ASSY. 4 Paper eject sensor PCB failure Replace the paper eject sensor PCB ASSY. 5 Main PCB failure Replace the main PCB ASSY.