Causes: Combination error between the machine production/remodeling and the firmware
Remedy: Check the combination between the machine production/remodeling and the firmware.
Code: A0-22
Description: Machine level error (SCU detection)
Causes: Combination error between the machine production/remodeling and the firmware
Remedy: Check the combination between the machine production/remodeling and the firmware.
Code: C1-01
Description: Charger cleaner trouble
Causes: The charger cleaner does not complete shift operation during the specified time.
Remedy: Case 1 Cause Charger unit trouble Check and remedy Check the charger unit Case 2 Cause RE sensor, HP sensor, charger cleaner motor, and PCU PWB troubles, harness connection trouble Check and remedy 1) Check the sensor, the motor, and the PCU PWB. 2) Check the harness connection between the sensor, the motor and the PCU PWB.
Code: C1-02
Description: Charger cleaner motor lock
Causes: When the charger cleaner motor is rotating, an excess motor current over the specified level is detected.
Remedy: Case 1 Cause Charger cleaner motor trouble Check and remedy Check the charger cleaner motor Case 2 Cause PCU PWB trouble, harness connection trouble Check and remedy 1) Check the PCU PWB. 2) Check harness connection between the motor and the PCU PWB.
Code: C4-00
Description: PTC (Pre-Transfer Charger) high voltage output trouble
Causes: A trouble signal is detected during PTC high voltage output.
Remedy: Case 1 Cause Charger wire breakage Check and remedy Check the charger unit. Case 2 Cause PTC high voltage PWB trouble Check and remedy Replace the PTC high voltage PWB. Case 3 Cause PCU PWB trouble Check and remedy Replace the PCU PWB. Case 4 Cause Connector and harness connection trouble Check and remedy Check connection of the connector and the harness.
Causes: Shifting the PTC cleaner is not completed within the specified time.
Remedy: Case 1 Cause Cleaner mechanism trouble Check and remedy Check the cleaner mechanism. Case 2 Cause HP sensor trouble Check and remedy Replace the HP sensor. Case 3 Cause Cleaner motor trouble Check and remedy Replace the cleaner motor. Case 4 Cause PCU PWB trouble Check and remedy Replace the PCU PWB. Case 5 Cause Connector and harness connection trouble Check and remedy Check connection of the connector and the harness.