Description: Wiper Protection Error Even though the machine carries out the regular movement, the output of the Wiper Origin Sensor does not reach the expected value.
Causes: Disorder of Wiper Origin Sensor Fault of Wiper Unit Fault of Wiper Origin Sensor Cut-line or short-circuit of Cable and Flexible Cable
Remedy: 1) Check Cable Connection of the Servo Board. 2) Check Cable Connection of the Junction Board. 3) Wiper Motor Replacement 4) Wiper Unit Replacement 5) Wiper Sensor Replacement 6) Cable and Flexible Cable Replacement
Code: 0110
Description: Linear Encoder Error Input value from Linear Encoder is not changed when Linear Encoder is set up the Origin. When Motor stops during printing, Motor does not complete the movement which is supposed to be done.
Causes: Read error of Linear Encoder Read error of Encoder on Scan Motor side Wire is not fixed to Head Carriage firmly.
Remedy: 1) Confirm whether Encoder Scale is between the slit of Encoder Module in a whole width of the machine. 2) Linear Encoder Replacement 3) Scan Motor Replacement 4) Confirm Cable Connection between Linear Encoder Board and Print Carriage Board. 5) Confirm Connection between Belt and Head Carriage. 6) Main Board Replacement
Code: 0120
Description: Thermistor error (Print heater) The abnormalities of a thermistor for Print heater
Causes: The device is abnormal. The thermistor wiring has short-circuited or come down.ble Cable
Remedy: Checking the wiring Thermistor replacement
Code: 0121
Description: Thermistor error (Pre-heater R) The abnormalities of a thermistor for Pre-heater R
Causes: The device is abnormal. The thermistor wiring has short-circuited or come down.
Remedy: Checking the wiring Thermistor replacement
Code: 0122
Description: Thermistor error (Pre-heater F) The abnormalities of a thermistor for Pre-heater F
Causes: The device is abnormal. The thermistor wiring has short-circuited or come down.
Remedy: Checking the wiring Thermistor replacement
Code: 0125
Description: Heater error (Print heater) The abnormalities of a heater The temperature of the heater has reached 60 degree C or higher.
Causes: The heater wiring is abnormal. The thermoregulator is abnormal (not work).