Description: Receiving buffer is in abnormal conditions.
Remedy: Replace the CPU circuit board with a new one.
Code: 08
Display: ERROR 08 POWER
Description: Supply voltage for driving the motor is abnormal.
Remedy: Check the supply voltage. Replace the power circuit board with a new one. Replace the driver circuit board with a new one.
Code: 10
Display: ERROR 10 COMMAND
Description: Unbreakable command code is received
Remedy: Check the communication conditions. Perform a loopback test to check whether the device normally operates. If the device maloperates, replace the CPU circuit board with a new one.
Code: 11
Display: ERROR 11 PARAMETER
Description: A parameter that is outside the specified range of values is received.
Remedy: Check the communication conditions. Perform a loopback test to check whether the device normally operates. If the device maloperates, replace the CPU circuit board with a new one.
Code: 12
Display: ERROR 12 DEVICE
Description: Cutting (plotting) cannot be initiated since an amount of data exceeding the capacity of the receiving buffer is sent from thehost computer and no plot start command is present in the receiving buffer. Device command is abnormal.
Remedy: Check the communication conditions. Perform a loopback test to check whether the device normally operates. If the device maloperates, replace the CPU circuit board with a new one. Send an amount of data within the capacity of the receiving buffer from the host computer. If the device normally operates with the data, check the host computer. Check the communication conditions. Perform a loopback test to check whether the device normally operates. If the device maloperates, replace the CPU circuit board with a new one.
Code: 13
Display: ERROR 13 POLYGON
Description: Polygon data sent exceeds the capacity of polygon buffer.