Causes: • If the Image scanner home position sensor does not detect the Image scanner within 18898 pulses after the Flat bed read pulse motor is activated. • If the Image scanner ADF Shading sensor does not detect the Image scanner within 15748 pulses after the Flat bed read pulse motor is activated. • If the scanner home position sensor does not detect the Image scanner within 14,551 pulses(462 mm worth) after the Flat bed read pulse motor is activated during prescanning. • If the Image scanner is not release from the Image scanner home position sensor within 314 pulses after the Flat bed read pulse motor is activated. • If the Image scanner is not released from the Image scanner ADF Shading sensor within 314 pulses after the Flat bed read pulse motor is activated.
Remedy: Press <ALL RESET> key.
Code: T16
Description: Position C Sensor Malfunction
Causes: • If the Position C sensor status has not been changed from ON to OFF (or OFF to ON) within 8 seconds from the start of the Main Motor.
Remedy: Press <ALL RESET> key.
Code: T17
Description: Replace Battery
Causes: • When the battery voltage is less than 2.4 V at power-on, all reset, or end of operation.
Remedy: Power OFF -> ON
Code: T18
Description: Sorter Error
Causes: • If an error signal is received from the sorter.
Remedy: Power OFF -> ON
Code: T19
Description: Thermal Pressure Motor Lock
Causes: • If the TPH Pressure switch has not been depressed within 4 seconds after the TPH Pressure motor was activated to lower the TPH. • If the TPH Pressure switch has not been released within 4 seconds after the TPH Pressure motor was activated to raise the TPH.
Remedy: Press <ALL RESET> key.
Code: T2
Description: Elevator Motor Lock
Causes: • In 15 seconds from turning ON of the Elevator motor in upward direction, the Elevator upper limit sensor is not pushed. • In 15 seconds from turning ON of the Elevator motor in downward direction, the light path of the Elevator lower limit sensor is not blocked. • In 3 seconds from turning ON of the Elevator motor in upward direction, the Elevator lower sensor is held blocked. • In 3 seconds from turning ON of the Elevator motor in downward direction, the Elevator upper limit sensor is held pressed down.