  • Code: SC231-01 ... SC231-04
  • Description: SC231- 01 D FGATE OFF error: Bk
    SC231- 02 D FGATE OFF error: Cy
    SC231- 03 D FGATE OFF error: Ma
    SC231- 04 D FGATE OFF error: Ye
    • The FGATE signal did not turn OFF within the specified time (sec.) after the writing process of the corresponding color ended.
    • The FGATE signal did not turn OFF when the next job of the corresponding color started.
  • Causes: • Image processing ASIC defective on IPU
    • Harness between IPU and LDB defective
  • Remedy: 1. Turn the main power OFF/ON.
    2. Reconnect the connectors between IPU and controller board.
    3. Replace the IPU.
  • Code: SC240-01 ... SC240-04
  • Description: SC240- 01 D LD error: Bk
    SC240- 02 D LD error: Cy
    SC240-03 D LD error: Ma
    SC240- 04 D LD error: Ye
    • If LD error terminal of LD driver of corresponding color is asserted after LD initialization.
    • If an error is detected during initialization of LD driver which detects Ith/Ieta of LD of corresponding color.
  • Causes: • LD degradation (LD broken, shift of output characteristics etc.)
    • The interface harness damaged or not connected correctly.
    • LD driver defective
  • Remedy: 1. Turn the main power OFF/ON.
    2. Check the value in SP2-110-001 to 004 (LD Driver), the default is "0h". • If current value is "0", perform step 4. • If current value is "1", perform steps 3 and 5.
    3. Reconnect the connectors between LDB and IPU.
    4. Replace the LD unit
    5. Replace the harness between LDB to IPU.
  • Code: SC272-01 ... SC272-04
  • Description: SC272-01 D LD driver communication error: Bk
    SC272-02 D LD driver communication error: Cy
    SC272-03 D LD driver communication error: Ma
    SC272-04 D LD driver communication error: Ye
    In view of parity, 3 retries were performed
  • Causes: • BCU defective
    • Harness defective
    • LDB defective
  • Remedy: 1. Turn the main power OFF/ON.
    2. Reconnect the following connectors: • LDB-IPU harness • IPU-BCU harness
    3. Replace the LD unit.
    4. Replace the BCU.
    5. Replace the following harnesses: • LDB-IPU harness • IPU-BCU harness
  • Code: SC272-10
  • Description: LD driver communication error: Other
    LD voltage does not satisfy the specified voltage (5 V).
  • Causes: • BCU defective (LD5V Power error)
    • LDB defective (LD drive error)
    • LDB connector defective (loose, broken)
    • Interlock switch defective
  • Remedy: 1. Turn the main power OFF/ON.
    2. Reconnect the connectors between LDB and IPU.
    3. Replace the IPU.
    4. Replace the LD unit.
    5. Replace the harness between LDB and IPU.
    6. Replace the interlock switch.
  • Code: SC285-01
  • Description: Laser Optics Positioning Motor (in LD unit) Power Control Error
    The power supply from PSU is not supplied to the laser optics positioning motors.
  • Causes: • Software error
    • Imaging IOB defective
    • BCU defective
  • Remedy: 1. Turn the main power OFF/ON.
    2. Update the firmware.
    3. Replace the imaging IOB.
    4. Replace the BCU.
  • Code: SC285-02
  • Description: MUSIC error
    The results of MUSIC pattern reading failed 4 times. (even if mode e (real time MUSIC) fails, the error count is not incremented (+1))
  • Causes:
  • Remedy: