PrintCopy.info service

Ricoh M132 SP8300DN AL-P2

Error Codes List page 2

  • Code: 230
  • Description: FGATE ON error The FGATE signal does not assert within the prescribed time. (The bridge board generates the FGATE signal and sends it to the LD unit when the registration sensor switches on.)
  • Causes: • BCU, Controller board harness loose or broken • Controller board defective • BCU defective
  • Remedy:
  • Code: 231
  • Description: FGATE OFF error The FGATE signal does not assert within the prescribed time. (The bridge board generates the FGATE signal and sends it to the LD unit when the registration sensor switches on.)
  • Causes: • BCU, Controller board harness loose or broken • Controller board defective • BCU defective
  • Remedy:
  • Code: 240
  • Description: LD error The bridge board detected a problem at the LD unit.
  • Causes: • Worn-out LD • Disconnected or broken harness of the LD.
  • Remedy:
  • Code: 270
  • Description: GAVD communication error • The I2C bus device ID is not identified during initialization. • A device-status error occurs during I2C bus communication. • The I2C bus communication is not established due to an error other than a buffer shortage.
  • Causes: • BCU, Bridge board harness loose or broken • Defective bridge board • Defective BCU • Defective LD controller board
  • Remedy:
  • Code: 302
  • Description: Charge roller bias leak A charge roller bias leak signal was detected.
  • Causes: • Charge roller damaged • High voltage supply board defective • PCDU harness defective or disconnected
  • Remedy:
  • Code: 304
  • Description: Charge roller bias correction leak The charge roller bias correction is performed twice even if the maximum charge roller bias (-2000V) is applied to the roller.
  • Causes: • ID sensor defective • Worn charge roller • Charge roller damaged
  • Remedy:
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us