Remedy: 1. Replace the polygon motor. 2. Replace the laser optics housing unit. 3. Replace the harness. 4. Replace the IPU.
Code: 220
Description: Laser synchronization detection error: LD0 The laser synchronizing detection signal for the start position of the LD was not output for two sec. after LDB unit turned on with the polygon motor rotating normally.
Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the IPU.
Code: 230
Description: FGATE ON error The FGATE signal did not assert within the prescribed time. (The BCU generates the FGATE signal and sends it to the LD unit when the registration sensor switches on.)
Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.
Code: 231
Description: FGATE OFF error The FGATE signal did not go off within the prescribed time. (The BCU generates the FGATE signal and sends it to the LD unit when the registration sensor switches on.)