Description: BICU error: abnormal LSYNC The error result of the self-diagnostic by the ASIC on the BICU is detected at power on or recovery from the energy save mode.
Causes: Defective BICU. Defective connection between BICU and SBU.
Remedy: 1. Check the connection between BICU and SBU. 2. Replace the BICU.
Code: 162-01
Description: BICU error: PCIE communication error The link up interrupt from LYRA is not detected or the number of connection lanes is other than 2 at power on or recovery from the energy save mode.
Causes: Defective BICU. Defective connection between BICU and SBU
Remedy: 1. Check the connection between BICU and SBU. 2. Replace the BICU.
Code: 165
Description: Copy Data Security Unit error The copy data security board is not detected or a device check error occurs when the copy data security function is set "ON" with the initial setting.
Causes: Incorrect installation of the copy data security board. Defective copy data security board
Remedy: 1. Reinstall the copy data security board. 2. Replace the copy data security board.
Code: 195
Description: Serial Number Mismatch Serial number stored in the memory does not have the correct code.
Causes: EEPROM defective. BICU replaced without original EEPROM
Remedy: 1. Check the serial number with SP5-811-002. 2. If the stored serial number is incorrect, contact your supervisor.
Code: 202-01
Description: Polygon motor error 1: ON timeout: Bk, Cy The polygon mirror motor does not reach the targeted operating speed within the specified time after turning on or changing speed
Causes: Defective or disconnected harness to polygon motor driver board. Defective polygon motor driver board. Defective polygon motor
Remedy: 1. Replace the polygon motor. 2. Replace the laser optics housing unit. 3. Replace the harness. 4. Replace the BICU.
Code: 202-03
Description: Polygon motor error 1: ON timeout: Ma, Ye The polygon mirror motor does not reach the targeted operating speed within the specified time after turning on or changing speed
Causes: Defective or disconnected harness to polygon motor driver board. Defective polygon motor driver board. Defective polygon motor
Remedy: 1. Replace the polygon motor. 2. Replace the laser optics housing unit. 3. Replace the harness. 4. Replace the BICU.