PrintCopy.info service

Ricoh D015 MPC7500SP V-C2

Error Codes List page 2

  • Code: SC144
  • Description: SBU communication error
    When the machine is switched on, or when the machine returns to full operation from the energy save mode, the machine can not access the SBU register, or the SBU register values are abnormal. Note: The ASIC IDs read during automatic adjustment of the SBU can be displayed with SP4600.
  • Causes: • SBU harness loose, disconnected, defective • SBU board defective • VBCU defective
  • Code: SC161
  • Description: IPU error
    Communication error between IPU, SBU, and VBCU.
  • Causes: • Check harness connections between SBU and IPU/VBCU • IPU defective • VBCU defective
  • Code: SC165
  • Description: Illegal Copy Prevention Error
    An abnormality was detected with the ICIB board at power on.
  • Causes: • ICIB connected incorrectly • ICIB defective
  • Code: SC180
  • Description: Scanner fan lock The fan motor next to the SIOB did not switch on within 10 sec. after the CPU issued the ON signal.
  • Causes: • Fan defective • Foreign object interfering with operation of fan • Motor harness loose, disconnected, or broken • SIOB defective
  • Code: SC181
  • Description: Scanner Fan Error: Lamp Stabilizer
    The exposure lamp regulator fan is not rotating.
  • Causes: • Check the fan connections • Fan defective • Check SBU connection • Check SIOB connection • SBU defective • SIOB defective
  • Code: SC182
  • Description: Scanner Fan Error: Right Side
    The fan located on the right side of the exposure unit is not rotating.
  • Causes: • Check the fan connections • Fan defective • Check SBU connection • Check SIOB connection • SBU defective • SIOB defective