- Code: 054
- Display: Power OFF/ON
054 : Error - Description: A communication error of the scanner unit
A communication error was detected between the Controller and scanner unit. - Remedy: Record a value displayed far right at the bottom of LCD and turn on the power unit again.
- Code: 057
- Display: Power OFF/ON
057 : Error - Description: The timeout of command communication of the scanner
The timeout of command communication was detected between the Controller and scanner unit (A sub code indicates a cause). 01: There is no ACK for a command to start scanning. 02: There is no ACK for a command to cancel scanning. 03: There is no ACK for a command to cancel SU. - Remedy: Record a value displayed far right at the bottom of LCD and turn off/on the power unit.
- Code: 058
- Display: Power OFF/ON
058 : Error - Description: An error of the scanner controlling area
An internal error was detected in the scanner controlling area ofthe Controller. - Remedy: Record a value displayed far right at the bottom of LCD and turn off/on the power unit.
- Code: 062
- Display: Power OFF/ON
062 : Error - Description: USB Driver Error
- Remedy:
- Code: 064
- Display: Inspection is required.
064 : Error - Description: SD Card Missing Error
- Remedy: Is a SD Card installed in the unit, properly? No Reinstall the SD card.
- Code: 069
- Display: Inspection is required.
069 : Error - Description: NIC Chip Error