PrintCopy.info service

OKI MC760

Error Codes List page 3

  • Code: C3E2
  • Description: The fuse has blown out.
  • Remedy: Is the belt unit connected normally? Does this error recur?
    Re-install the belt unit. Turn on the power again. After checking for the sure cable connection, replace the PU or Board IBY.
  • Code: C3EA ... C3ED
  • Description: The ID unit fuse has blown out. (C3EA=Y, C3EB=M, C3EC=C, C3ED=K)
  • Remedy: Is the ID unit installed normally? Does this error recur? Does the printer recover from the error when the PU/PRZ board is replaced?
    Re-install the ID unit. Turn on the power again. After checking for the sure connection of the cable between PRZ board and PU board, replace the PRZ board. Replace the PU board.
  • Code: C41A, C41B
  • Description: Short-circuit or opencircuit of fuser thermistor is detected.
  • Remedy: Does this error recur? Yes Turn on the power again. Replace the fuser unit.
  • Code: C41C
  • Description: The backup roller thermistor is detected of its short-circuit. (At high temperature)
  • Remedy: Does this error recur? Yes Turn on the power again. Replace the fuser unit.
  • Code: C41D
  • Description: The backup roller thermistor is detected of its opencircuit. (At low temperature)
  • Remedy: Does this error recur? Yes Turn on the power again. Replace the fuser unit.
  • Code: C41E
  • Description: Compensation Thermistor Error
  • Remedy: Is the error message displayed? Does this error recur? Yes Turn on the power again. After leaving a printer for 30 minutes, turn on the power again.