  • Code: 06
  • Display: ERROR 06 UHC 02 nnnn
  • Description: . UHC status ready turned OFF. n=UHC No.1-8
  • Remedy: 1) Check that UHCII PCB is inserted securely in the main PCB. 2) Turn ON/OFF the plotter and check the problem disappears. 3) Upgrade the firmware.
  • Code: 06
  • Display: ERROR 06 UHC 03 nnnn
  • Description: . Waiting for UHC bus busy cancellation. 5sec timeout. n=UHC No.1-8
  • Remedy: 1) Check that UHCII PCB is inserted securely in the main PCB. 2) Turn ON/OFF the plotter and check the problem disappears. 3) Upgrade the firmware.
  • Code: 06
  • Display: ERROR 06 UHC 04 nnnn
  • Description: . Waiting for UHC status Read. 5sec timeout. n=UHC No.1-8
  • Remedy: 1) Check that UHCII PCB is inserted securely in the main PCB. 2) Turn ON/OFF the plotter and check the problem disappears. 3) Upgrade the firmware.
  • Code: 06
  • Display: ERROR 06 UHC 05 nnnn
  • Description: . Waiting for UHC response. 5sec timeout. n=UHC No.1-8.
  • Remedy: 1) Check that UHCII PCB is inserted securely in the main PCB. 2) Turn ON/OFF the plotter and check the problem disappears. 3) Upgrade the firmware.
  • Code: 06
  • Display: ERROR 06 UHC 06 nnnn
  • Description: . UHC status: Receiving FIFO full. Waiting for cancellation. 10sec timeout. n=UHC No.1-8
  • Remedy: 1) Check that UHCII PCB is inserted securely in the main PCB. 2) Turn ON/OFF the plotter and check the problem disappears. 3) Upgrade the firmware.
  • Code: 06
  • Display: ERROR 06 UHC 07 nnnn
  • Description: . UHC status: Waiting for band memory clear. 10msec timeout. n=UHC No.1-8
  • Remedy: 1) Check that UHCII PCB is inserted securely in the main PCB. 2) Turn ON/OFF the plotter and check the problem disappears. 3) Upgrade the firmware.