Description: • The Y-axis motor has been overloaded. • The brush of motor is in abnormal conditions.
Remedy: 1) Clean the main guide axis. 2) Replace Y axis motor. 3) Replace a main PCB.
Code: 42
Display: ERROR42 X CURRENT
Description: • Overcurrent error has arisen on the X-axis motor
Remedy: 1) Replace X axis motor. 2) Replace a main PCB.
Code: 43
Display: ERROR43 Y CURRENT
Description: • Overcurrent error has arisen on the Y-axis motor
Remedy: 1) Replace Y axis motor. 2) Replace a main PCB.
Code: 45
Display: ERROR45 CAPPING
Description: • The capping-control is in abnormal conditions.
Remedy: 1) Turn on the power. 2) Replace a slider PCB. 3) Replace a cap sensor. 4) Replace a IO PCB. 5) Replace a station sensor. 6) Replace a station motor.
Code: 46
Display: ERROR46 WIPER
Description: • The wiper-control is in abnormal conditions
Remedy: 1) Turn on the power. 2) Replace a wiper assy. 3) Replace IO PCB. 4) Replace a wiper sensor. 5) Replace a wiper motor.
Code: 50
Display: ERROR50 MEDIA SENSE
Description: • Media detection has not been successfully carried out.
Remedy: 1) Make sure that there is no gap between platen F (aluminum) and the edge of the P cover F rubber. If there is a gap, stick the rubber appressed against the platen. The gap may be detected in mistake. 2) Make sure that platen cover F is fixed securely using the platen cover F mounting screws (attached on auxiliary side plates R and L to prevent the cover from protruding). 3) Check if the media right edge is set at a position 15mm or more from the rightmost edge of the rightmost feed roller:R1 toward the station side or not. 4) Cleaning or replace a paper width sensor. 5) Replace a main FPC cable. 6) Replace a slider PCB. 7) Replace a HDC-4Head PCB. 8) Replace a main PCB.