Description: • The Linear encoder is in abnormal conditions.
Remedy: 1) Replace the Linear encoder with a new one. 2) Replace the main PCB with a new one.
Code: 09
Display: ERROR09 HDC
Description: • Configuration of PDC/IOC has not been successfully carried out. • Configuration of HDC has not been successfully carried out.
Remedy: 1) Replace the main PCB with a new one. 2) Replace the HDC PCB with a new one.
Code: 10
Display: ERROR10 COMMAND
Description: • Command code other than MRL has been received.
Remedy: 1) Check the data received through HEX dump. 2) If error occurs at 1394 a. Check Time out of the transfer tool (RIP). b. Replace the I/F connection board with [E102154A] or later. c. Replace the 1394 board with a new one. d. Replace the main PCB with a new one.
Code: 11
Display: ERROR11 PARAMETER
Description: • Parameter that has not defined in MRL has been received.
Remedy: 1) Check the data received through HEX dump. 2) If error occurs at 1394 a. Check Time out of the transfer tool (RIP). b. Replace the I/F connection board with [E102154A] or later. c. Replace the 1394 board with a new one. d. Replace the main PCB with a new one.
Code: 12
Display: ERROR12 Ment Command
Description: • A command error for manufacture of has occurred .
Remedy: 1) It is not used in the field.
Code: 20
Display: ERROR20 I/F BOARD
Description: • A error occurred in communication between the main PCB and the interface board.
Remedy: 1) Replace the I/F PCB with a new one. 2) Replace the main PCB with a new one. 3) Replace the I/F connection board with a new one.