  • Code: E-0010
  • Description: Main Motor Error
    The Main Motor Output Detection Signal (MAINM_LD) continues to be “H” for 3 seconds or longer when the Main Motor is rotating.
  • Remedy: Wires 1 Is the wire between Main Motor and PW11720 PCB connected properly? No Connect it properly. Confirm that the machine is turned on, and then check the voltage of the orange line (J220-5). Is it 24V? No Replace the DC Power Supply if there is no problem with the wires. DC Power Supply (DCP1) or Fuse 2 Confirm that the machine is turned off, and then check whether or not each Fuse is broken. Is any Fuse broken? Yes Replace the Fuse. Main Motor (M1) 3 Check the operation of Main Motor in the Operation Check Mode of the Service Mode. Device Code : 00 (Main Motor) Does the Main Motor operate correctly? No Replace the Main Motor.
  • Code: E-0013
  • Description: Paper Tray Motor Error
    The Paper Tray Motor Output Detection Signal (CSETM_LD) continues to be “H” for 3 seconds or longer when the Paper Tray Motor is rotating.
  • Remedy: Wires 1 Is the wire between Paper Tray Motor and PW11720 PCB connected properly? No Connect it properly. Confirm that the machine is turned on, and then check the voltage of the orange line. Is it 24V? No Replace the DC Power Supply if there is no problem with the wires. DC Power Supply (DCP1) or Fuse 2 Confirm that the machine is turned off, and then check whether or not each Fuse is broken. Is any Fuse broken? Yes Replace the Fuse. Paper Tray Motor (M3) 3 Check the operation of Main Motor in the Operation Check Mode of the Service Mode. Device Code : 33 (Paper Tray Motor) Does the Main Motor operate correctly? No Replace the Main Motor.
  • Code: E-0020
  • Description: Counter Error
    The Counter Connection Detection Signal (COUNT_OPN) continues to be “L” for 1 second or longer after turning on.
  • Remedy: Service Mode 1 Has the setting of Adjustment Mode Item No.753 set to “1” ? Yes Set it to “0”.
  • Code: E-0031
  • Description: Image Corona Output Error
    The Image Corona Output Detection Signal (IM_LD) continues to be “L” for 1 second or longer when the Image Corona is ON.
  • Remedy: Wire 1 Are wires among Image Corona, HV Power Supply PCB and PW11720 PCB connected properly? No Connect them properly. 2 (For Image Corona / Cleaning Roller only) Is the spring on the left bottom of the Process Unit OK? No Correct it properly. Is the Image Corona dirty? Yes Clean each Corona Wire, Grid Plate and housing. Image Corona 3 Is the Corona Wire broken? Yes Replace the Corona Wire. Does the bias terminal plate touch to Cleaning Roller shaft properly? No Remove and reapply conductive grease to Cleaning Roller shaft. Relocate the bias terminal plates properly. Cleaning Roller 4 Is grease applied enough? No Remove and reapply conductive grease to Cleaning Roller shaft. Is the Transfer Corona dirty? Yes Clean each Corona Wire and housing. Transfer Corona 5 Is the Corona Wire broken? Yes Replace the Corona Wire. Is the Separation Corona dirty? Yes Clean each Corona Wire and housing. Separation Corona 6 Is the Corona Wire broken? Yes Replace the Corona Wire. HV Power Supply 7 Can you fix the problem if you replace the HV Power Supply? Yes OK
  • Code: E-0032
  • Description: Separation Corona Output Error
    The Separation Corona Output Detection Signal (AC_LD) continues to be “L” for 1 second or longer when the Separation Corona is ON.
  • Remedy: Wire 1 Are wires among Image Corona, HV Power Supply PCB and PW11720 PCB connected properly? No Connect them properly. 2 (For Image Corona / Cleaning Roller only) Is the spring on the left bottom of the Process Unit OK? No Correct it properly. Is the Image Corona dirty? Yes Clean each Corona Wire, Grid Plate and housing. Image Corona 3 Is the Corona Wire broken? Yes Replace the Corona Wire. Does the bias terminal plate touch to Cleaning Roller shaft properly? No Remove and reapply conductive grease to Cleaning Roller shaft. Relocate the bias terminal plates properly. Cleaning Roller 4 Is grease applied enough? No Remove and reapply conductive grease to Cleaning Roller shaft. Is the Transfer Corona dirty? Yes Clean each Corona Wire and housing. Transfer Corona 5 Is the Corona Wire broken? Yes Replace the Corona Wire. Is the Separation Corona dirty? Yes Clean each Corona Wire and housing. Separation Corona 6 Is the Corona Wire broken? Yes Replace the Corona Wire. HV Power Supply 7 Can you fix the problem if you replace the HV Power Supply? Yes OK
  • Code: E-0033
  • Description: Transfer Corona Output Error
    The Transfer Corona Output Detection Signal (TR_LD) continues to be “L” for 1 second or longer when the Transfer Corona is ON.
  • Remedy: Wire 1 Are wires among Image Corona, HV Power Supply PCB and PW11720 PCB connected properly? No Connect them properly. 2 (For Image Corona / Cleaning Roller only) Is the spring on the left bottom of the Process Unit OK? No Correct it properly. Is the Image Corona dirty? Yes Clean each Corona Wire, Grid Plate and housing. Image Corona 3 Is the Corona Wire broken? Yes Replace the Corona Wire. Does the bias terminal plate touch to Cleaning Roller shaft properly? No Remove and reapply conductive grease to Cleaning Roller shaft. Relocate the bias terminal plates properly. Cleaning Roller 4 Is grease applied enough? No Remove and reapply conductive grease to Cleaning Roller shaft. Is the Transfer Corona dirty? Yes Clean each Corona Wire and housing. Transfer Corona 5 Is the Corona Wire broken? Yes Replace the Corona Wire. Is the Separation Corona dirty? Yes Clean each Corona Wire and housing. Separation Corona 6 Is the Corona Wire broken? Yes Replace the Corona Wire. HV Power Supply 7 Can you fix the problem if you replace the HV Power Supply? Yes OK