Remedy: 1. Reset the malfunction. 2. Check that the Original Glass is properly installed. 3. Check the optical system. 4. If the optical system has been checked okay, change Memory Board.
Remedy: 1. Reset the malfunction. 2. Check that the Original Glass is properly installed. 3. Check for extraneous light and check to see if the CCD Assy and mirrors are installed at the correct positions. 4. If the same malfunction is detected again, change Image Processing Board.
Code: C1450
Description: Sequence trouble timeout
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, check the cables, timing belt, and other drive transmission mechanism from the Scanner Motor to the Scanner. 3. If step 2 has been checked okay, change Image Processing Board.
Code: C1461
Description: Serial GA1 failure
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.
Code: C1462
Description: Serial GA2 failure
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.
Code: C1470
Description: Module-to-module communication (CCM-EVM)
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.