Description: Fuser Motor Error The Fuser Motor is having an error.
Causes: 1. The Fuser Motor is overloaded because of exit area jam or some other reason. 2. The high voltage may be leaking anywhere.
Remedy: 1) Remove the media jamming in the exit area, if it exists. 2) Check the action of the Fuser Unit and the Fuser Motor in the Output Checking Mode of the Service Mode. 3) Check whether the driving system, such as gears, of the Fuser Unit is damaged or not. 4) Check whether the high voltage is leaking or not on any charger. 5) Check whether the connection between Fuser Motor and Motor Driver PCB is firmly or not. 6) Check the fuse on the Motor Driver PCB.
Code: E30
Description: Developer Unit Connection Error
Causes: The Developer Unit is not connected to the machine.
Remedy: 1) Check whether the connector (SM connector 11P) of the Developer Unit is disconnected or not, or whether it is damaged or not, for example the pin is broken. 2) Replace the Main PCB.
Code: E32
Description: Upper Size Selector Error Error
Causes: The Upper Size Selector is having some error.
Remedy: 1) Check the position of the Selector Knob on the Size Selector. 2) Check whether the Size Selector is correctly installed or not. 3) Check whether any pin is pulled out or not from the connector J16 on the Main PCB. 4) Check whether the Drawer Connector, which connects the Roll Deck to the machine when the deck is closed, is connected firmly or not. 5) Check whether the Size Selector is having some error or not in the Media / Size Selector Checking Mode of the Service Mode. 6) Replace the Size Selector. 7) Replace the Main PCB.
Code: E33
Description: Lower Size Selector Error
Causes: The Lower Size Selector is having some error.
Remedy: 1) Check the position of the Selector Knob on the Size Selector. 2) Check whether the Size Selector is correctly installed or not. 3) Check whether any pin is pulled out or not from the connector J16 on the Main PCB. 4) Check whether the Drawer Connector, which connects the Roll Deck to the machine when the deck is closed, is connected firmly or not. 5) Check whether the Size Selector is having some error or not in the Media / Size Selector Checking Mode of the Service Mode. 6) Replace the Size Selector. 7) Replace the Main PCB.
Code: E34
Description: Self Diagnosis Error Either of following errors occurs during Self Diagnosis which is taken when you turn on the machine.
Causes: The IC1 on the Main PCB is broken or not put into the socket proper.
Remedy: Input some Setting Data in the Toner Level Setting Mode (mode 4) of the Service Mode 1.
Code: E34e1
Description: EE PROM Error
Causes: 1. The IC11 on the Main PCB is having some error. 2. The IC23 on the Main PCB is having some error.