Description: Fixing Thermistor high temperature detection error. The Fixing Film Unit Thermistor (Rear) detected an abnormally high temperature.
Causes: - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 2 (THM13/J8003) - Fixing Film Unit - Pickup Driver PCB (UN4)
Remedy: Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. 1. Check the harness between the Pickup Driver PCB and the Fixing Film Unit Thermistor (Rear). 2. Pull out the Fixing Feed Unit and check "FIX-UCE". a. In the case of below 240 deg C, replace the Fixing Film Unit. b. In the case of 240 deg C or higher, disconnect the connector of the Pickup Driver PCB and then check "FIX-UCE" again. b-a. In the case of below 240 deg C, replace the harness between the Pickup Driver PCB and the Drawer Unit. b-b. In the case of 240 deg C or higher, replace the Pickup Driver PCB.
Code: E001-0015-05
Description: Fixing Thermistor high temperature detection error. The Fixing Film Unit Thermistor (Front) detected an abnormally high temperature.
Causes: - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 1 (THM11/J7404) - Fixing Film Unit - Pickup Driver PCB (UN4)
Remedy: Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. 1. Check the harness between the Pickup Driver PCB and the Fixing Film Unit Thermistor (Front). 2. Pull out the Fixing Feed Unit and check "FIX-UE2". a. In the case of below 240 deg C, replace the Fixing Film Unit. b. In the case of 240 deg C or higher, disconnect the connector of the Pickup Driver PCB and then check "FIX-UE2" again. b-a. In the case of below 240 deg C, replace the harness between the Pickup Driver PCB and the Drawer Unit. b-b. In the case of 240 deg C or higher, replace the Pickup Driver PCB.
Code: E002-0001-05
Description: Fixing Thermistor temperature increase detection error. After the Fixing Heater was turned ON, the Fixing Main Thermistor detected no temperature increase.
Causes: - Harness connecting the DC Controller PCB (J122), Drawer Unit (J5012) - Harness connecting the AC Driver PCB (J502), Drawer Unit (J5012) - DC Controller PCB - Fixing Film Unit - Shutter Unit
Remedy: Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR.
Code: E003-0001-05
Description: Fixing Thermistor low temperature detection error. The Fixing Main Thermistor detected an abnormally low temperature during print control.
Causes: - Harness connecting the DC Controller PCB (J122), Drawer Unit (J5012) - Harness connecting the AC Driver PCB (J502), Drawer Unit (J5012) - DC Controller PCB - Fixing Film Unit - Shutter Unit
Remedy: Perform the following in the order while checking whether the error is cleared. 1. Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. Then, turn OFF and then ON the main power. 2. Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR.
Code: E004-0001-05
Description: Fixing relay welding detection error. Welding of the fixing relay on the AC Driver PCB was detected.
Causes: - DC Controller PCB - AC Driver PCB
Remedy: Perform the following in the order while checking whether the error is cleared. 1. Replace the AC Driver PCB . 2. Replace the DC Controller PCB . [Caution] If it is left as it is, other fixing-related errors (E001 to E003) may occur.
Code: E004-0201-05
Description: Fixing Thermistor temperature error. An error in temperature difference between the Fixing Film Unit Sub Thermistor 1 and 2 was detected.
Causes: - Harnesses connecting the Pickup Driver PCB (N4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 2 (J8003) - Harness between the Relay PCB (UN7/J1816) and the Fixing Motor (M48/J7612) - Fixing Film Unit - Fixing Motor (M48) - Pickup Driver PCB (UN4) - Relay PCB (UN7)
Remedy: Check/replace the related harness/cable, connector and parts.