Description: The rise in temperature of the fixing unit is inadequate.
The output of the non-contact thermistor does not reach 90°C within 180 sec after it has reached 60°C.
Code: E002-0004
Description: The rise in temperature of the fixing unit is inadequate.
The output of the non-contact thermistor does not reach 120°C within 240 sec after it has reached 90°C.
Code: E002-0005
Description: The rise in temperature of the fixing unit is inadequate.
The output of the non-contact thermistor does not reach 140°C within 180 sec after it has reached 120°C.
Code: E002-0006
Description: The rise in temperature of the fixing unit is inadequate.
The output of the non-contact thermistor does not reach 160°C within 180 sec after it has reached 140°C.
Code: E002-0007
Description: The rise in temperature of the fixing unit is inadequate.
The output of the non-contact thermistor does not reach 180°C within 180 sec after it has reached 160°C.
Code: E002-0008
Description: The rise in temperature of the fixing unit is inadequate.
The output of the non-contact thermistor does not reach 190°C within 180 sec after it has reached 180°C.