Kyocera ECOSYS M3560

Siveen
Posts: 40
Joined: Mon Feb 01, 2021 12:24 pm

Kyocera ECOSYS M3560

Postby Siveen » Sat Oct 09, 2021 5:09 pm

No image (blank page)
How to fix?
Alvin
Posts: 58
Joined: Mon Feb 01, 2021 12:31 pm

Re: Kyocera ECOSYS M3560

Postby Alvin » Sat Oct 09, 2021 5:19 pm

Kyocera ECOSYS M3040dn, M3040idn, M3540dn, M3540idn, M3550idn, M3560idn
No image appears (entirely white).
Scanning
  1. Contact glass assy
    Check the location the contact glass is mounted.
    Re-mount the contact glass if it is hanged off.
  2. FFC cable CCD
    Check the FFC cable between the CCD and control PWB is properly connected. Or, verify conduction of the wire.
    Reinsert the connector if it its connection is loose. Or, if conduction is lot, replace the wire.
  3. Home position sensor
    Check the location the home position sensor is mounted.
    Re-mount the home position sensor if it is hanged off.
  4. Scanner drive belt
    Check that the scanner drive belt is loosely mounted.
    If the scanner drive belt is loosely mounted, secure the screws.
  5. Scanner drive gear
    Check that the scanner drive gear is loosely mounted.
    If the scanner drive gear loosely mounted, secure the screw.
  6. CCD PWB
    The CCD PWB is defective.
    Replace the ISU and perform U411.
  7. Control PWB
    The control PWB is defective.
    Replace the control PWB.
DP-scanning
  1. Original document
    Verify the sides of the original document.
    If the sides of the original document are reversed, place the original document properly.
  2. Contact glass assy
    Check the location the contact glass is mounted.
    Re-mount the contact glass if it is hanged off.
  3. FFC cable CCD
    Check the FFC cable between the CCD and control PWB is properly connected. Or, verify conduction of the wire.
    Reinsert the connector if it its connection is loose. Or, if conduction is lot, replace the wire.
  4. Home position sensor
    Check the location the home position sensor is mounted.
    Re-mount the home position sensor if it is hanged off.
  5. Scanner drive belt
    Check that the scanner drive belt is loosely mounted.
    If the scanner drive belt is loosely mounted, secure the screws.
  6. Scanner drive gear
    Check that the scanner drive gear is loosely mounted.
    If the scanner drive gear loosely mounted, secure the screw.
  7. CCD PWB
    The CCD PWB is defective.
    Replace the ISU and perform U411.
  8. Control PWB
    The control PWB is defective.
    Replace the control PWB.
Alvin
Posts: 58
Joined: Mon Feb 01, 2021 12:31 pm

Re: Kyocera ECOSYS M3560

Postby Alvin » Sat Oct 09, 2021 5:24 pm

Kyocera ECOSYS M3040dn, M3040idn, M3540dn, M3540idn, M3550idn, M3560idn
No image appears (entirely black).
Scanning
  1. FFC cable CCD
    Check the FFC cable between the CCD and control PWB is properly connected. Or, verify conduction of the wire.
    Reinsert the connector if its connection is loose. Or, if conduction is lot, replace the wire.
  2. CCD PWB
    The CCD PWB is defective.
    Replace the ISU and perform U411.
  3. Control PWB
    The control PWB is defective.
    Replace the control PWB.
DP-scanning
  1. Scanning position of the DP
    Confirm the value using maintenance mode U068, DP Read.
    If a large value is observed in maintenance mode U068, DP Read, perform adjustment.
  2. FFC cable CCD
    Check the FFC cable between the CCD and control PWB is properly connected. Or, verify conduction of the wire.
    Reinsert the connector if its connection is loose. Or, if conduction is lot, replace the wire.
  3. CCD PWB
    The CCD PWB is defective.
    Replace the ISU and perform U411.
  4. Control PWB
    The control PWB is defective.
    Replace the control PWB.
Alvin
Posts: 58
Joined: Mon Feb 01, 2021 12:31 pm

Re: Kyocera ECOSYS M3560

Postby Alvin » Sat Oct 09, 2021 7:58 pm

Kyocera ECOSYS M3040dn, M3040idn, M3540dn, M3540idn, M3550idn, M3560idn
Image is too light.
Scanning
  1. The settings of theadjustment of density
    Check the settings of the adjustment of density.
    1. Deactivate EcoPrint if it is activated. Or, if the density is too low, chosse an image quality that suits the original docuemt in type.
    2. Increase density.
    3. Perform the background color adjustment using the system menu.
  2. Settings of anti-offset
    Check the settings of anti-offset.
    If anti-offset is set to on, set it to off.
  3. Adjustment of the scanner
    Check the automatic adjustment of the scanner.
    Perform maintenance mode U411, table(Chart1)_All.
  4. Contact glass
    Check whether the contact glass is dirty.
    If the contact glass is dirty, clean the contact glass, and the bottom part of the shading plate.
  5. Home position sensor
    Check the location the home position sensor is mounted.
    Re-mount the home position sensor if it is hanged off.
  6. FFC cable CCD
    Check the FFC cable between the CCD and control PWB is properly connected. Or, verify conduction of the wire.
    Reinsert the connector if its connection is loose. Or, if conduction is lot, replace the wire.
  7. Lamp unit
    Check the location the lamp unit is mounted.
    Re-mount the lamp unit if it is hanged off.
  8. LED PWB
    Check that the LED is lit.
    If the LED is not lit, replace the ISU and perform U411.
  9. CCD PWB
    CCD PWB is defective.
    Replace the ISU and perform U411.
  10. Control PWB
    The control PWB is defective.
    Replace the control PWB.
DP-scanning
  1. The settings of the adjustment of density
    Check the settings of the adjustment of density.
    1. Deactivate EcoPrint if it is activated. Or, if the density is too low, chosse an image quality that suits the original docuemt in type.
    2. Increase density.
    3. Perform the background color adjustment using the system menu.
  2. Settings of anti-offset
    Check the settings of anti-offset.
    If anti-offset is set to on, set it to off.
  3. Adjustment of the scanner
    Check the automatic adjustment of the scanner.
    Perform maintenance mode U411, table(Chart1)_All.
  4. Contact glass
    Check whether the contact glass is dirty.
    If the contact glass is dirty, clean the contact glass, and the bottom part of the shading plate.
  5. Home position sensor
    Check the location the home position sensor is mounted.
    Re-mount the home position sensor if it is hanged off.
  6. Scanning position of the DP
    Check whether the scanning position of the DP is wrong.
    If the scanning position of the DP is shifted, perform maintenance mode U068, DP Read.
  7. FFC cable CCD
    Check the FFC cable between the CCD and control PWB is properly connected. Or, verify conduction of the wire.
    Reinsert the connector if its connection is loose. Or, if conduction is lot, replace the wire.
  8. Lamp unit
    Check the location the lamp unit is mounted.
    Re-mount the lamp unit if it is hanged off.
  9. LED PWB
    Check that the LED is lit.
    If the LED is not lit, replace the ISU and perform U411.
  10. CCD PWB
    CCD PWB is defective.
    Replace the ISU and perform U411.
  11. Control PWB
    The control PWB is defective.
    Replace the control PWB.

Return to “Kyocera ECOSYS”