Riso FR Series

Peter
Posts: 51
Joined: Sat Oct 21, 2017 9:46 pm

Riso FR Series

Postby Peter » Thu Oct 14, 2021 9:11 am

Riso FR Series, FR2950, FR3910, FR3950
TEST MODE
Starting Up Test mode
  1. Turn on the power, pressing down both <M/P> and <LINE/PHOTO> buttons on the main panel.
  2. Input a test mode No. by using panel-keys.
  3. Press <START> key to start operation.
  4. Press <START> key one more time to stop operation.
  5. To select another Test mode, clear the set Test No. by pressing the <C> or <STOP> button and select another Test No.
Exiting from the Test mode
  • To exit from a Test mode, clear the set Test No. by pressing the <C> or <STOP> button and then press the <ALL RESET> button.
Bill
Posts: 63
Joined: Sat Oct 21, 2017 9:50 pm

Re: Riso FR Series

Postby Bill » Thu Oct 14, 2021 9:18 am

Riso FR Series, FR2950, FR3910, FR3950
Memory Clear and Counter Stop, etc.

90 Partial Memory Clear
Certain portion of RAM contents in the System PCB, such as Jam and Trouble messages, will be initialized.
(The same operation as when turning the power ON while pressing All Reset button

92 Prevention of the following operations: master and copy counting, Key/card counter
• In normal operation, the Master count and Copy count signals will not be output, allowing a service technician to print without increasing the digit of the Master and Copy counters.
• The machine will be released from this condition when the power is turned off.
CAUTION: Do not use this mode when TM5000 is in connection.

93 Maintenance master counter clear
Displays/clears the maintenance master counter value. The <C> key clears the count value and the <START > key settles it.

94 Maintenance print counter clear
Displays/clears the maintenance master print counter value. The <C> key clears the count value and the <START> key settles it.

97 All Memory Clear
All RAM contents in the System PCBs, excluding Memory switch setting by Test modes, will be initialized.
Master disposal count is not cleared.
NOTE: This test mode must be done each time System ROM, System PCB, or Battery is changed.

98 Memory Switch Clear
Memory switch settings by Test modes will be initialized.
This test mode must be done each time System PCB is changed.
CAUTION:
Do not use this test mode in normal operation. All the programmed Memory switch settings in the machine will be initialized.

Return to “Riso”

Who is online