Mutoh 1638wx Error message:
Full waste Ink Tank
Mutoh ValueJet VJ1638W
Re: Mutoh ValueJet VJ1638W
Error message: Full waste Ink Tank
Check and Action:
Check and Action:
- Check if Waste fluid bottle is full.
Dispose of waste fluid. - Check the connection of the connector of Waste fluid level switch.
Correctly insert the following connectors again.
JUNCTION board, Connector on the Waste fluid bottle side. - Waste fluid level switch may be damaged.
Replace Waste fluid level switch. If the same error continues to be displayed after replacing Waste fluid level switch:
JUNCTION board may be damaged. Replace it. - Check JUNCTION board.
Replace Waste fluid level switch. If the same error continues to be displayed after replacing Waste fluid level switch:
JUNCTION board may be damaged. Replace it.