Konica Minolta Di3010 error

Bill
Posts: 64
Joined: Sat Oct 21, 2017 9:50 pm

Konica Minolta Di3010 error

Postby Bill » Sun Oct 22, 2017 1:26 am

Code C0998. How to remove this code.
JasonAnype
Posts: 1
Joined: Tue Oct 20, 2020 3:06 pm

Konica Minolta Di3010 error

Postby JasonAnype » Wed Oct 21, 2020 5:21 pm

This topic is simply matchless :), it is interesting to me.
Sanjay
Posts: 45
Joined: Mon Feb 01, 2021 11:47 am

Re: Konica Minolta Di3010 error

Postby Sanjay » Sat Feb 20, 2021 6:14 am

Code: C0998 - LCC Shift Failure
  • The Shifter Return Position Sensor (PC11-LCC) is not unblocked even after the set period of time has elapsed after the shift operation has begun (shifter is moved to the right).
  • The Shifter Return Position Sensor (PC11-LCC) is not unblocked even after the set pulse is detected by the Shift Motor Pulse Sensor (PC8-LCC) after the shift operation has begun (shifter is moved to the right).
  • The Shifter Home Position Sensor (PC12-LCC) is not unblocked even after the set pulse is detected by the Shift Motor Pulse Sensor (PC8-LCC) after the shift operation has begun (shifter is moved to the right).
  • The Shifter Home Position Sensor (PC12-LCC) is not unblocked even after the set period of time has elapsed after the return operation has begun (shifter is moved to the left). • The Shifter Home Position Sensor (PC12-LCC) is not unblocked even after the set pulse is detected by the Shift Motor Pulse Sensor (PC8-LCC) after the return operation has begun (shifter is moved to the left).
  • The Shifter Return Position Sensor (PC11-LCC) is not unblocked even after the set pulse is detected by the Shift Motor Pulse Sensor (PC8-LCC) after the return operation has begun (shifter is moved to the left).
Solution:
  1. Check the connector for proper connection, and correct as necessary.
  2. PC8-LCC sensor check.
  3. PC11-LCC sensor check.
  4. PC12-LCC sensor check.
  5. Replace PWB-C1 LCC.