Remedy: (1) Turn the power OFF and start up the Setting Mode (08). (2) Key in “662” and press the [START] button. (Partition clearing is performed.) (3) Restart the equipment. (4) Access TopAccess. Click the [Administration] tab, and then click the Maintenance Menu to open. Then install the “Point and Print” driver.
Code: F107
Description: /BOX partition damage
Remedy: Initialize the Electronic Filing using the Setting Mode (08-666).
Code: F108
Description: /SHA partition damage
Remedy: Initialize the shared folder using the Setting Mode (08-667).
Code: F110
Description: Communication error between System-CPU and Scanner-CPU
Remedy: (1) Check if the connector CN104 on the SYS board and CN130, CN131, CN134 on the SYSIF board is disconnected. (2) Check if the connector CN10 on the SLG board is disconnected. (3) Check if the harness connecting the SYSIF board and SLG board is disconnected or open circuited. (4) Check if the harness connecting the SYSIF board and LGC board is disconnected or open circuited. (5) Check if the connection of the SYS board (CN104) and SYSIF board (CN130) is open circuited. (6) If the SYS board has been replaced, check if the jumper pin setting on the SYS board is correct. (The jumper pin should be inserted between pin 2 and 3 of CN103 and CN115.) (7) Check the version of the system ROM on the SYS board. (8) Check the version of the engine ROM version on the LGC board. (9) Check the version of the scanner ROM version on the SLG board. (10) Replace the SYS board. (11) Replace the SLG board. (12) Replace the LGC board. (13) Replace the SYSIF board.
Code: F111
Description: Scanner response abnormality
Remedy: (1) Check if the connector CN104 on the SYS board and CN130, CN131, CN134 on the SYSIF board is disconnected. (2) Check if the connector CN10 on the SLG board is disconnected. (3) Check if the harness connecting the SYSIF board and SLG board is disconnected or open circuited. (4) Check if the harness connecting the SYSIF board and LGC board is disconnected or open circuited. (5) Check if the connection of the SYS board (CN104) and SYSIF board (CN130) is open circuited. (6) If the SYS board has been replaced, check if the jumper pin setting on the SYS board is correct. (The jumper pin should be inserted between pin 2 and 3 of CN103 and CN115.) (7) Check the version of the system ROM on the SYS board. (8) Check the version of the engine ROM version on the LGC board. (9) Check the version of the scanner ROM version on the SLG board. (10) Replace the SYS board. (11) Replace the SLG board. (12) Replace the LGC board. (13) Replace the SYSIF board.
Code: F120
Description: Database abnormality: Databases do not run normally.
Remedy: (1) Rebuild the databases. (Perform 08-684.) (2) If the error is not recovered, initialize the HDD. (Key in “2” at 08-690.)