  • Code: C414
  • Description: Fuser unit related service call. Temperature of the fuser roller did not reach to "temperature for ready condition" at specified period of time during warming-up.
  • Causes: MAIN board Thermistors Heater lamp
  • Remedy: 1 Check the power voltage Check if the power voltage is normal. (Is the voltage during the operation ±10% of the rated voltage?) 2 Check the each elements of error status Check the abnormal thermistors 08-4570-0: Center thermistor 08-4570-1: Side thermistor 08-4570-2: Edge thermistor 08-4570-5: Error counter 3 Check the thermistors 1. Check if the connectors are disconnected. 2. Check if the center and edge thermistors are in contact with the surface of the fuser roller properly? 3. Check if the center and edge thermistors are not deformed or dirty. 4. Check if the harnesses of the center and edge thermistors are open circuited. 4 Check the heater 1. Check if the heater is broken. 2. Check if the connector of the heater is disconnected. 3. Check if the harnesses are connected properly to the terminals of the heater lamp. 4. Check if the thermostat is blown. 5 Check the MAIN board 1. Check if the connectors are disconnected. 2. Check if the conductor pattern on the MAIN board is short circuited or open circuited. 3. Replace the MAIN board. 6 Clear the status counter After repairing the matter which caused the error [C413 / C414], perform the following: 1. Turn ON the power while [0] and [8] are pressed simultaneously. 2. Key in "2002", then press [START]. 3. Change the current status counter value "1" or "2" to "0", then press [OK] (to cancel [C413 / C414]). 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.
  • Code: C415
  • Description: Fuser unit related service call. No recovery even after one minute elapses after low temperature WAIT state is entered during a printing operation.
  • Causes: MAIN board
  • Remedy: 1. Check the thermistors 1. Check if the connectors are disconnected. 2. Check if the center and edge thermistors are in contact with the surface of the fuser roller properly? 3. Check if the center and edge thermistors are not deformed or dirty. 4. Check if the harnesses of the center and edge thermistors are open circuited. 2. Check the heater 1. Check if the heater is broken. 2. Check if the connector of the heater is disconnected. 3. Check if the harnesses are connected properly to the terminals of the heater lamp. 4. Check if the thermostat is blown. 3. Check the MAIN board 1. Check if the connectors CN10 are disconnected. 2. Check if the conductor pattern on the MAIN board is short circuited or open circuited. 3. Replace the MAIN board 4. Check the power supply 1. Check if the connectors are disconnected. 2. Replace the switching regulator. 5. Clear the status counter After repairing the matter which caused the error [C415], perform the following: 1. Turn ON the power while [0] and [8] are pressed simultaneously. 2. Key in "2002", then press [START]. 3. Change the current status counter value "5" to "0", then press [OK] (to cancel [C415]). 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.
  • Code: C447
  • Description: Fuser unit related service call. While in the READY state, one of the thermistors detected the specified temperature or higher.
  • Causes: MAIN board
  • Remedy: 1. Check the thermistors 1. Check if the connectors are disconnected. 2. Check if the center and edge thermistors are in contact with the surface of the fuser roller properly? 3. Check if the center and edge thermistors are not deformed or dirty. 4. Check if the harnesses of the center and edge thermistors are open circuited. 2. Check the heater 1. Check if the heater is broken. 2. Check if the connector of the heater is disconnected. 3. Check if the harnesses are connected properly to the terminals of the heater lamp. 4. Check if the thermostat is blown. 3. Check the MAIN board 1. Check if the connectors CN10 are disconnected. 2. Check if the conductor pattern on the MAIN board is short circuited or open circuited. 3. Replace the MAIN board 4. Check the power supply 1. Check if the connectors are disconnected. 2. Replace the switching regulator. 5. Clear the status counter After repairing the matter which caused the error [C447], perform the following: 1. Turn ON the power while [0] and [8] are pressed simultaneously. 2. Key in "2002", then press [START]. 3. Change the current status counter value "7"or "24" to "0", then press [OK] (to cancel [C447]). 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.
  • Code: C449
  • Description: Fuser unit related service call. High temperature detection error
  • Causes: MAIN board
  • Remedy: 1. Check the thermistors 1. Check if the connectors are disconnected. 2. Check if the center and edge thermistors are in contact with the surface of the fuser roller properly? 3. Check if the center and edge thermistors are not deformed or dirty. 4. Check if the harnesses of the center and edge thermistors are open circuited. 2. Check the heater 1. Check if the heater is broken. 2. Check if the connector of the heater is disconnected. 3. Check if the harnesses are connected properly to the terminals of the heater lamp. 4. Check if the thermostat is blown. 3. Check the MAIN board 1. Check if the connectors CN10 are disconnected. 2. Check if the conductor pattern on the MAIN board is short circuited or open circuited. 3. Replace the MAIN board 4. Check the power supply 1. Check if the connectors are disconnected. 2. Replace the switching regulator. 5. Clear the status counter After repairing the matter which caused the error [C449], perform the following: 1. Turn ON the power while [0] and [8] are pressed simultaneously. 2. Key in "2002", then press [START]. 3. Change the current status counter value "9","19","21","22","23","25","27","29" or "45" to "0", then press [OK] (to cancel [C449]). 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.
  • Code: C452
  • Description: Fuser unit related service call. In the READY state, temperature differential error between the center thermistor and a side thermistor
  • Causes: MAIN board
  • Remedy: 1. Check the thermistors 1. Check if the connectors are disconnected. 2. Check if the center and edge thermistors are in contact with the surface of the fuser roller properly? 3. Check if the center and edge thermistors are not deformed or dirty. 4. Check if the harnesses of the center and edge thermistors are open circuited. 2. Check the MAIN board 1. Check if the connectors CN10 are disconnected. 2. Check if the conductor pattern on the MAIN board is short circuited or open circuited. 3. Replace the MAIN board 3. Clear the status counter After repairing the matter which caused the error [C452], perform the following: 1. Turn ON the power while [0] and [8] are pressed simultaneously. 2. Key in "2002", then press [START]. 3. Change the current status counter value "62" to "0", then press [OK] (to cancel [C452]). 4. Turn the power OFF and then back ON. M
  • Code: C4B0
  • Description: Fuser unit related service call. Fixer counter data error
  • Causes: MAIN board
  • Remedy: 1. Check the MAIN board 1. Check if the conductor pattern on the MAIN board is short circuited or open circuited. 2. Check if the Memory(IC11) is installed properly. 3. Replace the MAIN board 2. Clear the status counter After repairing the matter which caused the error [C4B0], perform the following: 1. Turn ON the power while [0] and [8] are pressed simultaneously. 2. Key in "2002", then press [START]. 3. Rewrite the displayed counter with "0" and then press the [OK] button ([C4B0] clear). 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.