Causes: Installation error of the CIS unit harness. Copy lamp lighting trouble. Dirt on the reference white plate. CIS unit trouble. DSPF PWB trouble. Shading adjustment error
Remedy: Check the installing state of the harness the CIS unit. Clean the reference white plate. Check the CIS unit. Check the DSPF PWB.
Code: E6-14
Description: CIS-ASIC error
Causes: DSPF PWB trouble.
Remedy: Replace the DSPF PWB.
Code: E7-01
Description: MFP image data error
Causes: Image data transfer error in the MFP PWB. MFP PWB trouble.
Remedy: Check connection of the connector and the harness of the MFP PWB. Replace the MFP PWB.
Code: E7-03
Description: HDD trouble
Causes: Connector, harness connection trouble in the MFP PWB and HDD. HDD error file management area data abnormality (FAT breakage). MFP PWB trouble.
Remedy: Check connection of the connector and the harness of the MFP PWB and HDD. Use SIM62-2,3 to check read/write operations of the HDD. Replace the HDD. Replace the MFP PWB.
Code: E7-04
Description: HDD-ASIC error
Causes: HDD-ASIC trouble. An error occurs in the HDD-ASIC self test when booting.
Causes: Improper insertion of the memory. Garbled memory data. The memory capacity is not the specified level.