  • Code: U2-04
  • Description: EEPROM read/write error (Serial communication error)
    EEPROM access process error
  • Causes: EEPROM abnormality
  • Remedy: Check that the EEPROM is properly set. Use SIM 16 to cancel the trouble. Replace the MCU PWB.
  • Code: U2-11
  • Description: Counter check sum error (EEPROM)
    Check sum error of the counter area in the EEPROM
  • Causes: EEPROM abnormality
  • Remedy: Check that the EEPROM is properly set. Use SIM 16 to cancel the trouble. Replace the MCU PWB.
  • Code: U9-00
  • Description: Panel board communication trouble.
    Communication trouble with the panel board.
  • Causes: No command can be sent from the MCU to the panel.
  • Remedy: MCU PWB - Panel PWB harness trouble. Replace the panel or the MCU PWB. Machine reset (Power OFF/ON).
  • Code: U9-80
  • Description: Panel board communication trouble (Protocol).
    An error occurs in communication between MCU -Panel PWB.
  • Causes: MCU PWB - Panel PWB harness trouble/ Garbled data.
  • Remedy: MCU PWB - Panel PWB harness trouble. Replace the panel or the MCU PWB. Machine reset (Power OFF/ON).
  • Code: U9-81
  • Description: Panel board communication trouble (Parity).
    A parity error occurs in communication between the MCU and the Panel PWB.
  • Causes: MCU PWB - Panel PWB harness trouble/ Garbled data.
  • Remedy: MCU PWB - Panel PWB harness trouble. Replace the panel or the MCU PWB. Machine reset (Power OFF/ON).
  • Code: U9-82
  • Description: Panel board communication trouble (Overrun).
    An overrun error occurs in communication between the MCU and the panel board.
  • Causes: MCU PWB - Panel PWB harness trouble/ Garbled data.
  • Remedy: MCU PWB - Panel PWB harness trouble. Replace the panel or the MCU PWB. Machine reset (Power OFF/ON).