PrintCopy.info service

Sharp MXB201D

Error Codes List page 5

  • Code: L1 00
  • Description: Feeding is not completed within the specified time after starting feeding. (The scan head locking switch is locked). The white area and the black marking on the shading plate are used to obtain the difference in the CCD level values for judgment of lock. When the difference in the levels of which and black is small, it is judged that the black mark could not be scanned by lock and the trouble code "L1" is displayed.
  • Causes: The scan head is locked by the lock switch. Mirror unit abnormality The scanner wire is disconnected. The origin detection sensor abnormality Mirror motor harness abnormality
  • Remedy: Check to confirm that the scan head lock switch is released. Use SIM 1-1 to check the mirror reciprocating operations. When the mirror does not feed. Check for disconnection of the scanner wire. Check the harness and the connector between the mirror motor and the MCU PWB. Replace the mirror unit. Replace the MCU PWB. When the mirror does feed. Use SIM 1-2 to check the mirror home position sensor.
  • Code: L3 00
  • Description: Scanner return trouble. When the mirror base is returned for the specified time (6 sec) in mirror initializing after turning on the power, the mirror home position sensor (MHPS) does not turn ON. Or when the mirror base is returned for the specified time (about 6 sec) after start of copy return, the mirror home position sensor (MHPS) does not turn ON.
  • Causes: Mirror unit abnormality Scanner wire disconnection Origin detection sensor abnormality Mirror motor harness abnormality
  • Remedy: Use SIM 1-1 to check the mirror reciprocating operations. When the mirror does not return. Check for disconnection of the scanner wire. Check the harness and the connector between the mirror motor and the MCU PWB. Replace the mirror unit. Replace the MCU PWB. When the mirror does feed. Use SIM 1-2 to check the mirror home position sensor.
  • Code: L4 01
  • Description: Main motor lock detection. When the main motor encoder pulse is not detected for 100 msec.
  • Causes: Main motor unit abnormality Improper connection or disconnection the main motor and the harness. MCU PWB abnormality
  • Remedy: Use SIM 25-01 to check the main motor operations. Check connection of the main motor harness/connector. Replace the main motor. Replace the MCU PWB.
  • Code: L4 31
  • Description: Fan motor lock detection trouble. The fan does not rotate. When sampling is made in an interval of 50msec, the normal signals are not detected 5 times continuously in 1 sec.
  • Causes: FAN trouble or harness contact trouble and disconnection.
  • Remedy: Check connection of the FAN harness and connector. Replace the FAN. Replace the MCU PWB.
  • Code: L6 10
  • Description: Polygon motor lock detection. The lock signal (specified rpm signal) does not return within a certain time (about 20 sec) from starting the polygon motor rotation.
  • Causes: Polygon motor unit abnormality Improper connection or disconnection of the polygon motor and the harness. MCU PWB abnormality
  • Remedy: Use SIM 61-1 to check the polygon motor operations. Check connection of the polygon motor harness/connector. Replace the polygon motor. Replace the MCU PWB.
  • Code: U1 03
  • Description: Network board battery error. The RTC backup battery voltage on network PWB falls.
  • Causes: The RTC backup battery voltage on network PWB falls.
  • Remedy: Check voltage of the RTC back up battery. Replace the battery.