Catalog
-
Sign In
-
Contacts
-
Forum
-
Eng
Sharp ARC360P
Error Codes List page 2
|
|
- Code: 031
- Display: Service Call 031: Error
- Description: CU Slot2 DIMM RAM Check Error
- Causes: Is subject RAM DIMM set properly? Is error recovered by replacing subject ROM DIMM?
- Remedy: Reset subject RAM DIMM. Replace RAM DIMM. Replace TIG board. (Replace EEPROM)
- Code: 032
- Display: Service Call 032: Error
- Description: CU Slot3 DIMM RAM Check Error
- Causes: Is subject RAM DIMM set properly? Is error recovered by replacing subject ROM DIMM?
- Remedy: Reset subject RAM DIMM. Replace RAM DIMM. Replace TIG board. (Replace EEPROM)
- Code: 035
- Display: Service Call 035: Error
- Description: Slot1 RAM Spec Error. The CU RAM Slot1 DIMM specification is not supported.
- Causes: Is RAM DIMM genuine? Is subject RAM DIMM gap setting proper? Is error recovered by replacing subject ROM DIMM?
- Remedy: Use genuine RAM DIMM. Reset subject RAM DIMM. Replace RAM DIMM. Replace TIG board. (Replace EEPROM)
- Code: 036
- Display: Service Call 036: Error
- Description: Slot2 RAM Spec Error. The CU RAM Slot2 DIMM specification is not supported.
- Causes: Is RAM DIMM genuine? Is subject RAM DIMM gap setting proper? Is error recovered by replacing subject ROM DIMM?
- Remedy: Use genuine RAM DIMM. Reset subject RAM DIMM. Replace RAM DIMM. Replace TIG board. (Replace EEPROM)
- Code: 037
- Display: Service Call 037: Error
- Description: Slot3 RAM Spec Error. The CU RAM Slot3 DIMM specification is notsupported.
- Causes: Is RAM DIMM genuine? Is subject RAM DIMM gap setting proper? Is error recovered by replacing subject ROM DIMM?
- Remedy: Use genuine RAM DIMM. Reset subject RAM DIMM. Replace RAM DIMM. Replace TIG board. (Replace EEPROM)
- Code: 040
- Display: Service Call 040: Error
- Description: CU EEPROM Error
- Causes: Is error recovered by replacing EEPROM on CU board?
- Remedy: Replace EEPROM. (Recover user environment.) Replace TIG board. (Replace EEPROM)