  • Code: E7 21
  • Description: LED controller initial trouble (Cyan)
  • Causes: The initial process of the LED controller cannot be completed properly.
  • Remedy: Case 1 Cause Disconnection of the LED head connector. Check & Remedy Check connection of the LED head connector Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit. Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.
  • Code: E7 22
  • Description: LED controller initial trouble (Magenta)
  • Causes: The initial process of the LED controller cannot be completed properly.
  • Remedy: Case 1 Cause Disconnection of the LED head connector. Check & Remedy Check connection of the LED head connector Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit. Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.
  • Code: E7 23
  • Description: LED controller initial trouble (Yellow)
  • Causes: The initial process of the LED controller cannot be completed properly.
  • Remedy: Case 1 Cause Disconnection of the LED head connector Check & Remedy Check connection of the LED head connector. Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit. Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.
  • Code: E7 24
  • Description: LED controller output trouble (Black)
  • Causes: When printing, the print end signal for each page is not properly provided
  • Remedy: Case 1 Cause Disconnection of the LED head connector. Check & Remedy Check connection of the LED head connector. Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit. Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.
  • Code: E7 25
  • Description: LED controller output trouble (Cyan)
  • Causes: When printing, the print end signal for each page is not properly provided.
  • Remedy: Case 1 Cause Disconnection of the LED head connector. Check & Remedy Check connection of the LED head connector. Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit. Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.
  • Code: E7 26
  • Description: LED controller output trouble (Magenta)
  • Causes: When printing, the print end signal for each page is not properly provided.
  • Remedy: Case 1 Cause Disconnection of the LED head connector. Check & Remedy Check connection of the LED head connector. Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit. Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.