Error Codes List page 15
|
|
- Code: L8-10
- Description: Power abnormality detection trouble
The power status monitoring signal keeps power OFF state after passing the specified time (2sec).
- Causes: Circuit around the power status monitoring signal failure.
- Remedy: Check whether power status monitoring signal (PSSTS) on MCU PWB is OPEN or not. Replace MCU PWB.
- Code: PF-00
- Description: RIC communication error
The copy inhibit command from RIC is received.
- Causes: Judged by the host.
- Remedy: Inform to the host.
- Code: U1-01
- Description: FAX battery error
The SRAM backup battery voltage on FAX PWB falls.
- Causes: The SRAM backup battery voltage on FAX PWB falls.
- Remedy: Check voltage of the SRAM back up battery. Replace the battery.
- Code: U1-02
- Description: PANEL LOW battery error
The voltage of the panel clock function battery falls.
- Causes: The voltage of the panel clock function battery falls.
- Remedy: Check voltage of panel clock function battery. Replace the battery.
- Code: U2-04
- Description: EEPROM communication error
MCU PWB EEPROM access circuit failure
- Causes: EEPROM defective ICU PWB EEPROM access circuit failure
- Remedy: Check that the EEPROM is properly set. Clear trouble with SIM 16. Replace the MCU PWB.
- Code: U2-20
- Description: Machine speed code data error
The machine (Boot) speed information is not identical to the model code speed information.
- Causes: EEPROM defective SIM operation error
- Remedy: Check for matching of the machine and model information setting in SIM26-57.