  • Code: L8-10
  • Description: Power abnormality detection trouble
    The power status monitoring signal keeps power OFF state after passing the specified time (2sec).
  • Causes: Circuit around the power status monitoring signal failure.
  • Remedy: Check whether power status monitoring signal (PSSTS) on MCU PWB is OPEN or not. Replace MCU PWB.
  • Code: PF-00
  • Description: RIC communication error
    The copy inhibit command from RIC is received.
  • Causes: Judged by the host.
  • Remedy: Inform to the host.
  • Code: U1-01
  • Description: FAX battery error
    The SRAM backup battery voltage on FAX PWB falls.
  • Causes: The SRAM backup battery voltage on FAX PWB falls.
  • Remedy: Check voltage of the SRAM back up battery. Replace the battery.
  • Code: U1-02
  • Description: PANEL LOW battery error
    The voltage of the panel clock function battery falls.
  • Causes: The voltage of the panel clock function battery falls.
  • Remedy: Check voltage of panel clock function battery. Replace the battery.
  • Code: U2-04
  • Description: EEPROM communication error
    MCU PWB EEPROM access circuit failure
  • Causes: EEPROM defective ICU PWB EEPROM access circuit failure
  • Remedy: Check that the EEPROM is properly set. Clear trouble with SIM 16. Replace the MCU PWB.
  • Code: U2-20
  • Description: Machine speed code data error
    The machine (Boot) speed information is not identical to the model code speed information.
  • Causes: EEPROM defective SIM operation error
  • Remedy: Check for matching of the machine and model information setting in SIM26-57.