Description: Communication trouble with FAX PWB (Time-out)
Causes: Occurs when time is out without response in data communication between the FAX board and the MCU. Cancel method: Turn OFF/ON the power.
Code: H2 00
Description: Thermistor open detection
Causes: The fusing thermistor is open.
Code: H3 00
Description: Heat roller abnormally high temperature
Causes: The fusing temperature rises above 240°C.
Code: H4 00
Description: Heat roller abnormally low temperature
Causes: The fusing temperature does not reach 185°C within 27 sec of turning on the power, or the fusing temperature keeps at 140°C.
Code: L1 00
Description: Feeding is not completed within the specified time after starting feeding.
Causes: When the mirror base is returned for the specified time (6 sec) in mirror initializing after turning on the power, the mirror home position sensor (MHPS) does not turn OFF. Or when the mirror base is fed for the specified time (about 6 sec) after start of copy return, the mirror home position sensor (MHPS) does not turn OFF.
Code: L3 00
Description: Return is not completed within the specified time.
Causes: When the mirror base is returned for the specified time (6 sec) in mirror initializing after turning on the power, the mirror home position sensor (MHPS) does not turn ON.Or when the mirror base is returned for the specified time (about 6 sec) after start of copy return, the mirror home position sensor (MHPS) does not turn ON.