Display: Error: #A3-3211 Turn off then on Error: #A3-3212 Turn off then on
Description: The inner temperature sensor is defective.
Remedy: 1) Turn the machine off then on. If the error persists, turn the machine off again. 2) Enter the tech mode. Check the temperature sensor output. 3) If the sensor is defective, replace it. 4) If the temperature sensor is OK, replace the main board.
Code: A3-3311, A3-3312
Display: Error: #A3-3311 Turn off then on Error: #A3-3312 Turn off then on
Description: The outer temperature sensor is defective.
Remedy: 1) Turn the machine off then on. If the error persists, turn the machine off again. 2) Enter the tech mode. Check the temperature sensor output. 3) If the sensor is defective, replace it. 4) If the temperature sensor is OK, replace the main board.
Code: A3-3320
Display: Not proper room temp. Move set
Description: The value of the outer temperature sensor is out of normal area.
Remedy: 1) Check if the machine is installed in the proper area. 2) If the temperature sensor is defective, replace it.
Code: C2-2110
Display: Prepare Toner
Description: There is not enough toner in the yellow toner cartridge
Remedy: 1) Print the supply information report. Check the life remaining of the toner cartridge. 2) If its life is at the end, turn the machine off and replace the toner cartridge with new one.
Code: C2-2120, C2-2150
Display: Replace Toner
Description: The yellow toner cartridge is at the end of its life.
Remedy: 1) If its life is at the end, turn the machine off and replace the yellow toner cartridge with new one.
Code: C2-2160, C2-2170
Display: Replace Toner
Description: The yellow toner cartridge is at the end of its life.