PrintCopy.info service

Samsung SLM2070F

Error Codes List page 2

  • Code: S2–4110
  • Display: Door open. Close it.
  • Description: Top cover is open or the cover open switch is defective.
  • Remedy: 1) Check if the top cover is closed perfectly. Open and close it. 2) Remove the right cover. Check if the connection between the main board and SMPS/HVPS board is correct. 3) Check if the cover open switch on SMPS/HVPS board is operated properly. If it is defective, replace the SMPS/HVPS board.
  • Code: S3–3121
  • Display: Scanner Locked.
  • Description: CIS unit in the scanner does not move.
  • Remedy: 1) Check if the CIS unit moves when turning the machine off then on. 2) Check if the CIS cable is connected correctly. Reconnect it. 3) If the CIS unit is defective, replace it. 4) Check if there is any defective part in the scanner. Find and replace it. 5) If the problem persists, replace the main board.
  • Code: S6–3123
  • Display: Network Problem : IP Conflict
  • Description: Network has some problem. (IP address conflicts with that of other system. / Communication error / There is no response when checking the ping test.)
  • Remedy: Change the machine’s IP address. • Execute the Samsung Easy Printer Manager program. (Device setting - Network - IP address). Change the IP address. • In case of DHCP or Bootp, reboot the machine to receive a new IP address.
  • Code: S6–3210
  • Display: Error: #S6-3210 Turn off then on
  • Description: The communication error between the main board and the wireless board has occurred.
  • Remedy: 1) Check if the connection between the main board and the wireless board is normal. 2) If the connection is OK, replace the flat cable. 3) If the flat cable is OK, replace the WLAN board. 4) If the problem persists after replacing the WLAN board, replace the main board.
  • Code: U1–2320, U1–2330, U1–2340
  • Display: Error #U1-2320 Turn off then on Error #U1-2330 Turn off then on Error #U1-2340 Turn off then on
  • Description: The temperature control of fuser unit is abnormal. (U1–2320 : Open Heat Error / U1–2330 : Low Heat Error / U1–2340 : Over Heat Error)
  • Remedy: 1) Turn the machine off. Re-install the fuser unit. Then turn the machine on. Is the error message is disappeared? 2) If the problem persists, turn the machine off and remove the fuser unit. a) Check if the fuser connector is connected properly. b) Check if the input voltage is normal. c) Check if the thermistor is twisted or contaminated. 3) After confirming continuity in the fuser connector and the problem still exists; order an SMPS/HVPS and Fuser Unit and install as is necessary.
  • Code: U2–1112, U2–1113
  • Display: Error #U2-1112 Turn off then on Error #U2-1113 Turn off then on
  • Description: LSU Motor does not work normally.
  • Remedy: 1) Check if the LSU harness on the main board is connected properly. (picture- 1) 2) If it is OK, check that the LSU harness on LSU board is connected properly. (picture- 2,3) 3) Check if the LSU harness is defective. (picture- 4,5) 4) If the problem persists, replace the LSU. 5) If the problem persists after replacing LSU, replace the main board.
Error Code
Service Mode, Troubleshooting