PrintCopy.info service

Samsung SCX4729FW

Error Codes List page 3

  • Code: S2-4110
  • Display: Door open Close it
  • Description: Door is open or the cover open switch is defective.
  • Remedy: 1) Check if the front cover is closed perfectly. 2) Check if the connection between the main board and HVPS board is correct. 3) Check if the cover open switch on HVPS board is operated properly. If it is defective, replace the HVPS board.
  • Code: S3-3121
  • Display: Scanner Locked.
  • Description: CIS unit in the scanner does not move.
  • Remedy: 1) Check if the CIS unit moves when turning the machine off then on. 2) Check if the CIS cable is connected correctly. Reconnect it. 3) If the CIS unit is defective, replace it. 4) Check if there is any defective part in the scanner. Find and replace it. 5) If the problem persists, replace the main board.
  • Code: S6-3123
  • Display: Network Problem : IP Conflict
  • Description: Network has some problem. (IP address conflicts with that of other system. / Communication error / There is no response when checking the ping test.)
  • Remedy: Change the machine’s IP address. • Execute the Samsung Easy Printer Manager program. (Device setting - Network - IP address). Change the IP address. • In case of DHCP or Bootp, reboot the machine to receive a new IP address.
  • Code: U1-2320
  • Display: Error #U1-2320 Turn off then on
  • Description: The temperature control of fuser unit is abnormal. (Open Heat Error)
  • Remedy: 1) Turn the machine off. Re-install the fuser unit. Then turn the machine on. Is the error message is disappeared? 2) If the problem persists, turn the machine off and remove the fuser unit. Check if the fuser connector is connected properly. Check if the input voltage is normal.
  • Code: U1-2330, U1-2340
  • Display: Error #U1-2330 Turn off then on Error #U1-2340 Turn off then on
  • Description: The temperature control of fuser unit is abnormal. (Low Heat Error or Over Heat Error)
  • Remedy: 1) Turn the machine off. Re-install the fuser unit. Then turn the machine on. Is the error message is disappeared? 2) If the problem persists, turn the machine off and remove the fuser unit. a) Check if the fuser connector is connected properly. b) Check if the input voltage is normal. c) Check if the thermistor is twisted or contaminated.
  • Code: U2-1112, U2-1113
  • Display: Error #U2-1112 Turn off then on Error #U2-1113 Turn off then on
  • Description: LSU Motor does not work normally.
  • Remedy: 1) Execute the LSU motor test in EDC program. Check the LSU motor operation sound. 2) If there is no sound, remove the right cover. Check if the LSU harness on the main board is connected properly. (picture- ,) 3) If it is OK, remove the top cover. Check if the LSU harness on LSU board is connected properly. (picture- ,) 4) Check if the LSU harness is defective. (picture- ,) 5) Reconnect the LSU harness and then execute the LSU motor test in EDC program again. 6) If the problem persists, replace the LSU. 7) If the problem persists after replacing LSU, replace the main board.